We report the combined use of real-time photo-CIDNP NMR and stopped-flow fluorescence techniques to study the kinetic refolding of a set of mutants of a small globular protein, HPr, in which each of the four phenylalanine residues has in turn been replaced by a tryptophan residue. The results indicate that after refolding is initiated, the protein collapses around at least three, and possibly all four, of the side-chains of these residues, as (i) the observation of transient histidine photo-CIDNP signals during refolding of three of the mutants (F2W, F29W, and F48W) indicates a strong decrease in tryptophan accessibility to the flavin dye; (ii) iodide quenching experiments show that the quenching of the fluorescence of F48W is less efficient for the species formed during the dead-time of the stopped-flow experiment than for the fully native state; and (iii) kinetic fluorescence anisotropy measurements show that the tryptophan side-chain of F48W has lower mobility in the dead-time intermediate state than in both the fully denatured and fully native states. The hydrophobic collapse observed for HPr during the early stages of its folding appears to act primarily to bury hydrophobic residues. This process may be important in preventing the protein from aggregating prior to the acquisition of native-like structure in which hydrophobic residues are exposed in order to play their role in the function of the protein. The phenylalanine residue at position 48 is likely to be of particular interest in this regard as it is involved in the binding to enzymes I and II that mediates the transfer of a phosphoryl group between the two enzymes.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0022-2836(03)00507-2DOI Listing

Publication Analysis

Top Keywords

real-time photo-cidnp
8
photo-cidnp nmr
8
nmr stopped-flow
8
stopped-flow fluorescence
8
fully native
8
hydrophobic residues
8
rapid formation
4
formation non-native
4
non-native contacts
4
contacts folding
4

Similar Publications

Real-time nuclear magnetic resonance spectroscopy in the study of biomolecular kinetics and dynamics.

Magn Reson (Gott)

May 2021

Institute for Organic Chemistry and Chemical Biology, Center for Biomolecular Magnetic Resonance (BMRZ), Johann Wolfgang Goethe-Universität Frankfurt, Frankfurt 60438, Germany.

The review describes the application of nuclear magnetic resonance (NMR) spectroscopy to study kinetics of folding, refolding and aggregation of proteins, RNA and DNA. Time-resolved NMR experiments can be conducted in a reversible or an irreversible manner. In particular, irreversible folding experiments pose large requirements for (i) signal-to-noise due to the time limitations and (ii) synchronising of the refolding steps.

View Article and Find Full Text PDF

Photo-CIDNP NMR spectroscopy of amino acids and proteins.

Top Curr Chem

August 2014

DFG Research Center Molecular Physiology of the Brain (CMPB), European Neuroscience Institute Göttingen (ENI-G) and EXC 171 Microscopy at the Nanometer Range, Göttingen, Germany,

Photo-chemically induced dynamic nuclear polarization (CIDNP) is a nuclear magnetic resonance (NMR) phenomenon which, among other things, is exploited to extract information on biomolecular structure via probing solvent-accessibilities of tryptophan (Trp), tyrosine (Tyr), and histidine (His) amino acid side chains both in polypeptides and proteins in solution. The effect, normally triggered by a (laser) light-induced photochemical reaction in situ, yields both positive and/or negative signal enhancements in the resulting NMR spectra which reflect the solvent exposure of these residues both in equilibrium and during structural transformations in "real time". As such, the method can offer - qualitatively and, to a certain extent, quantitatively - residue-specific structural and kinetic information on both the native and, in particular, the non-native states of proteins which, often, is not readily available from more routine NMR techniques.

View Article and Find Full Text PDF

Refolding of ribonuclease A monitored by real-time photo-CIDNP NMR spectroscopy.

J Biomol NMR

June 2009

Department of Chemistry, Physical and Theoretical Chemistry Laboratory, University of Oxford, South Parks Road, Oxford OX13QZ, UK.

Photo-CIDNP NMR spectroscopy is a powerful method for investigating the solvent accessibility of histidine, tyrosine and tryptophan residues in a protein. When coupled to real-time NMR, this technique allows changes in the environments of these residues to be used as a probe of protein folding. In this paper we describe experiments performed to monitor the refolding of ribonuclease A following dilution from a high concentration of chemical denaturant.

View Article and Find Full Text PDF

Photo-CIDNP NMR methods for studying protein folding.

Methods

September 2004

Department of Chemistry, University of Oxford, Oxford Centre for Molecular Sciences, Physical and Theoretical Chemistry Laboratory, South Parks Road, Oxford OX1 3QZ, UK.

Chemically induced dynamic nuclear polarization (CIDNP) is a nuclear magnetic resonance phenomenon that can be used to probe the solvent-accessibility of tryptophan, tyrosine, and histidine residues in proteins by means of laser-induced photochemical reactions, resulting in significant enhancement of NMR signals. CIDNP offers good sensitivity as a surface probe of protein structure and is particularly powerful in time-resolved NMR measurements. Real-time, rapid-injection protein refolding experiments permit the observation of changes in the accessibility of specific residues during the folding process.

View Article and Find Full Text PDF

Rapid sample-mixing technique for transient NMR and photo-CIDNP spectroscopy: applications to real-time protein folding.

J Am Chem Soc

October 2003

Oxford Centre for Molecular Sciences, University of Oxford, Central Chemistry Laboratory, South Parks Road, Oxford, OX1 3QH, United Kingdom.

We describe the development and application of a novel rapid sample-mixing technique for real-time NMR (nuclear magnetic resonance) spectroscopy. The apparatus consists of an insert inside a conventional NMR tube coupled to a rapid injection syringe outside the NMR magnet. Efficient and homogeneous mixing of solutions in the NMR tube is achieved with a dead time of tens of milliseconds, without modification of the NMR probe or additional hardware inside the magnet.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!