A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of a new Aerodynamic Particle Sizer Spectrometer for size distribution measurements of solution metered dose inhalers. | LitMetric

Evaluation of a new Aerodynamic Particle Sizer Spectrometer for size distribution measurements of solution metered dose inhalers.

J Aerosol Med

3M Drug Delivery Systems Division, Inhalation Drug Delivery Laboratory, Saint Paul, Minnesota 55144, USA.

Published: August 2003

The ability of the Model 3320 and newer Model 3321 Aerodynamic Particle Sizer Spectrometer (APS) to make accurate mass-weighted size distribution measurements of solution metered dose inhalers (MDIs) was evaluated. Measurements of experimental HFA-134a beclomethasone dipropionate MDIs were made with both the APS 3320 and APS 3321 and compared to the Andersen Cascade Impactor (ACI). The mass-weighted size distribution measurements from the ACI and APS 3321 agreed well but were very different than the APS 3320 measurements. Evaluation of the APS 3320 size distribution measurements indicated that the presence of a few erroneous particle measurements caused a gross overestimation of the mass median aerodynamic diameter (MMAD) and geometric standard deviation (GSD). When a previously described technique was used to eliminate erroneous particle size measurements from the size distribution calculation, the MMAD and GSD from the APS 3320 agreed well with those from the ACI and APS 3321. The GSD from the APS 3321 and the APS 3320 after a mask was applied were slightly larger than from the ACI. It is believed that both APS instruments slightly underestimate the GSD while the ACI slightly overestimates the GSD. Further experiments were conducted using the APS 3321 to examine the influence of drug concentration and cosolvent level on the size distribution of solution formulation MDIs. The MMAD was shown experimentally and theoretically to be proportional to drug concentration to the one-third power. Cosolvent concentration had minimal influence on MMAD over the range examined. The measurements reported in this paper demonstrate that it is possible to obtain accurate mass-weighted size distribution measurements with the APS 3320 and APS 3321. These instruments allow for accurate size distribution measurements to be made in minutes as opposed to the hours required to conduct and analyze size distribution measurements from cascade impactors.

Download full-text PDF

Source
http://dx.doi.org/10.1089/089426803321919870DOI Listing

Publication Analysis

Top Keywords

size distribution
36
distribution measurements
28
aps 3320
24
aps 3321
24
aps
14
measurements
12
mass-weighted size
12
size
10
distribution
9
aerodynamic particle
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!