The AbioCor implantable replacement heart.

Ann Thorac Surg

Department of Surgery, Division of Thoracic and Cardiovascular Surgery, University of Louisville School of Medicine, Louisville, Kentucky, USA.

Published: June 2003

The AbioCor implantable replacement heart (IRH) is the first available totally implantable artificial heart. We recently initiated a multicenter trial of this device in patients with severe, irreversible biventricular failure. Patients who were not candidates for other therapies, including transplantation, were evaluated. All candidates were adults with inotrope-dependent biventricular failure, whose 30-day predicted mortality was higher than 70%. A three-dimensional computerized fit study predicted fit of the AbioCor thoracic unit in all recipients. At operation, the internal battery controller and transcutaneous energy transfer unit were placed. The AbioCor thoracic unit was placed in an orthotopic position after incision of the ventricals. There were 2 intraoperative deaths (due to intraoperative bleeding or aprotinin reaction). Four late deaths were recorded, 1 from multisystem organ failure and 3 cerebrovascular accidents. Autopsy revealed thrombus on the atrial struts of the 3 patients with cerebrovascular accident. Blood pumps and valves were clean on all patients. Significant morbidity was observed, primarily related to preexisting severity of illness. However, 3 patients recovered to the point of being able to take multiple trips outside of the hospital. Two patients were discharged from the hospital, with 1 patient being discharged home for more than 7 months. No significant device malfunctions or multi-system organ failure device-related infections were noted. The AbioCor IRH may be effective therapy for patients with end-stage heart failure. Many milestones have been achieved in the initial trial in humans, including the successful discharge of a patient to home and no significant device malfunctions. The occurrence of stroke is likely related to the presence of thrombus on the atrial struts and may be decreased as these atrial struts have been removed for future clinical implants.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0003-4975(03)00484-3DOI Listing

Publication Analysis

Top Keywords

atrial struts
12
abiocor implantable
8
implantable replacement
8
replacement heart
8
biventricular failure
8
abiocor thoracic
8
thoracic unit
8
organ failure
8
thrombus atrial
8
device malfunctions
8

Similar Publications

Silent Brain Infarction (SBI) is increasingly recognized in patients with cardiac conditions, particularly Atrial Fibrillation (AF) in elderly patients and those undergoing Transcatheter Aortic Valve Implantation (TAVI). While these infarcts often go unnoticed due to a lack of acute symptoms, they are associated with a threefold increase in stroke risk and are considered a precursor to ischemic stroke. Moreover, accumulating evidence suggests that SBI may contribute to the development of dementia, depression, and cognitive decline, particularly in the elderly population.

View Article and Find Full Text PDF

In this case report, we explore a novel technique to remove an embolized Watchman device (Boston Scientific) into the thoracic aorta endovascularly. The technique involves a wire + snare combination that is threaded through the metal struts of the Watchman. This combination technique along with the threading provides increased stability during removal and decreases the risk of the Watchman slipping from the devices and causing further embolization.

View Article and Find Full Text PDF

Background: Percutaneous left atrial appendage closure (LAAC) serves as an alternative prophylactic strategy for patients with non-valvular atrial fibrillation (AF) who cannot undergo anti-coagulation therapy. Proper management of associated complications is crucial to enhancing the procedure's success rate and mitigating perioperative risks and adverse events during follow-up.

Aims: This study aims to summarize our center's experience and strategies in managing procedural-related complications encountered in 512 cases of LAAC with or without ablation for AF conducted from January 2020 to December 2023.

View Article and Find Full Text PDF

Background: Implantation of the left atrial appendage occluder (LAAO) has been proven to prevent stroke effectively in patients with atrial fibrillation who cannot tolerate anticoagulants. Incomplete endothelization of LAAO may cause device-related thrombus, and currently no good image modality exists to clearly see LAAO endothelialization. We aimed to use coronary optic coherence tomography (OCT) to visualize LAAO endothelialization.

View Article and Find Full Text PDF

The WATCHMAN device offers a viable alternative to long-term oral anticoagulation for stroke prevention in nonvalvular atrial fibrillation, particularly for high-risk patients. Despite its success, device-related thrombosis (DRT) remains a concern, potentially restricting its wider use. We present an 83-year-old female Jehovah's Witness with atrial fibrillation who, after successful WATCHMAN device implantation, suffered multiple transient ischemic attacks six months later.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!