Studies investigating human papillomavirus (HPV) viral load as a risk factor in the development of squamous intraepithelial lesions (SILs) and cancer have often yielded conflicting results. These studies used a variety of HPV viral quantitation assays [including the commercially available hybrid capture 2 (HC 2) assay], which differ in their ability to account for differences in cervical cell collection, linear dynamic range of viral load quantitation, and determination of type-specific versus cumulative viral load measures. HPV-16 and HPV-18 viral quantitation using real-time PCR assays were performed to determine whether type-specific viral load measurements that adjust for specimen cellularity result in a different association between viral load and prevalent SIL and cancer, compared with HC 2 quantitation (which does not adjust for cellularity or multiple infections). In general, HPV-16 viral load as measured by real-time PCR increased linearly with increasing grade of SIL while HPV-18 measured using similar techniques increased through low-grade SIL (LSIL), with HPV-18 viral load among high-grade SIL and cancers near the level of cytologically normal women. HC 2 viral load, using the clinical 1.0 pg/ml cut point, differentiated cytologically normal women from women with any level of cytological abnormality (normal versus >/=LSIL) but did not change as lesion severity increased. There was no evidence for plateau of HC 2 at high copy numbers, nor was significant variability in total specimen cellularity observed. However, cumulative viral load measurements by HC 2, in the presence of multiple coinfections, overestimated type-specific viral load. Multiple infections were more common among women with no (32%) or LSIL (51%) [versus 23% in high-grade SIL/cancer], partially explaining the lack of a dose response using a cumulative HC2 viral load measure. The nonrandom distribution of multiple infections by case-control status and the apparent differential effect of viral load by genotype warrant caution when using HC 2 measurements to infer viral load associations with SIL and cancer.

Download full-text PDF

Source

Publication Analysis

Top Keywords

viral load
52
viral
15
load
13
multiple infections
12
hybrid capture
8
human papillomavirus
8
hpv viral
8
viral quantitation
8
cumulative viral
8
hpv-18 viral
8

Similar Publications

Quantitative Analysis of Hepatitis D Virus Using gRNA-Sensitive Semiconducting Polymer Dots.

Anal Chem

January 2025

State Key Laboratory of Integrated Optoelectronics, College of Electronics Science and Engineering, Jilin University, No. 2699 Qianjin Street, Changchun, Jilin 130012, P. R. China.

Hepatitis D virus (HDV) significantly influences the progression of liver diseases. Through clinical observations and database analyses, it has been established that patients coinfected with HDV and hepatitis B virus (HBV) experience accelerated progression toward cirrhosis, hepatocellular carcinoma (HCC), and liver failure compared to those infected solely with HBV. A higher viral load correlates with increased replicative activity, enhanced infectivity, and more severe disease manifestations.

View Article and Find Full Text PDF

A 58-year-old male, with a history of human immunodeficiency virus (HIV) and stage 4 left frontotemporal squamous cell carcinoma (SCC), presented with new-onset neck pain. He was diagnosed with HIV five years prior. The patient had a cluster of differentiation 4 (CD4) count of 53 cells/mm³ and a high viral load, later suppressed with bictegravir, emtricitabine, and tenofovir alafenamide (Biktarvy).

View Article and Find Full Text PDF

%diag_test: a generic SAS macro for evaluating diagnostic accuracy measures for multiple diagnostic tests.

BMC Med Inform Decis Mak

January 2025

Institute of Mathematical Sciences Centre for Health Analytics and Modelling (CHaM), Strathmore University, Nairobi, Kenya.

Background: Measures of diagnostic test accuracy provide evidence of how well a test correctly identifies or rules-out disease. Commonly used diagnostic accuracy measures (DAMs) include sensitivity and specificity, predictive values, likelihood ratios, area under the receiver operator characteristic curve (AUROC), area under precision-recall curves (AUPRC), diagnostic effectiveness (accuracy), disease prevalence, and diagnostic odds ratio (DOR) etc. Most available analysis tools perform accuracy testing for a single diagnostic test using summarized data.

View Article and Find Full Text PDF

Background: Therapeutic outcomes for patients infected by genetically divergent HIV-1/O are not well-known due to scarce data and the lack of an appropriate comparison with patients infected by pandemic HIV-1/M. We aimed to compare the immunological and virological response to cART between HIV-1/O and HIV-1/M patients followed in France.

Methods: All naïve HIV-1/O subjects initiating cART in France in ANRS-ORIVAO study were compared to naïve HIV-1/M subjects initiating cART in ANRS-COPANA cohort.

View Article and Find Full Text PDF

Few cases of tenofovir resistance have been reported, and the appropriate treatment for such cases remains unclear. We aimed to share a case of a chronic hepatitis B mono-infected patient with potential tenofovir resistance who required combined lamivudine and tenofovir therapy to achieve adequate viral suppression. The patient's viral load (plasma) was monitored using the cobas® hepatitis B virus Test on the cobas® 6800 system.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!