Balloon-assisted coil placement in wide-neck bifurcation aneurysms by use of a new, compliant balloon microcatheter.

AJNR Am J Neuroradiol

Department of Interventional Neuroradiology, Fondation Rothschild, 25-29 rue Manin, 75940 Paris Cedex 19, France.

Published: October 2003

Two types of balloon are usually employed to perform balloon-assisted coil placement in cerebral aneurysms: oval, guide-dependent balloons for sidewall aneurysms and round balloons for bifurcation aneurysms. We report on the use of a new, more compliant, guide-dependent oval balloon microcatheter to seal wide-neck bifurcation aneurysms with coils during endovascular occlusion.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8149036PMC

Publication Analysis

Top Keywords

bifurcation aneurysms
12
balloon-assisted coil
8
coil placement
8
wide-neck bifurcation
8
balloon microcatheter
8
aneurysms
5
placement wide-neck
4
aneurysms compliant
4
compliant balloon
4
microcatheter types
4

Similar Publications

Endoanchors for the distal fixation of iliac limb in endovascular aneurysm repair.

J Vasc Surg Cases Innov Tech

April 2025

Division of Vascular and Endovascular Surgery, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy.

This report details the case of an 84-year-old male with an infrarenal abdominal aortic aneurysm and a dilated right common iliac artery eligible for endovascular treatment. A bifurcated stent graft (Medtronic Endurant IIs) was used to treat the aneurysm. To address the concerns of instability of the right iliac limb, four endoanchors (Heli-FX EndoAnchor, Medtronic) were placed at the distal landing zone to provide additional fixation.

View Article and Find Full Text PDF

Accurate rupture risk assessment is essential for optimizing treatment decisions in patients with cerebral aneurysms. While computational fluid dynamics (CFD) has provided critical insights into aneurysmal hemodynamics, most analyses focus on blood flow patterns, neglecting the biomechanical properties of the aneurysm wall. To address this limitation, we applied Fluid-Structure Interaction (FSI) analysis, an integrative approach that simulates the dynamic interplay between hemodynamics and wall mechanics, offering a more comprehensive risk assessment.

View Article and Find Full Text PDF

Purpose: The use of surgeon-modified fenestrated endograft to treat a bleeding complication in the common iliac artery.

Technique: An Endurant limb graft was modified on back table in theater after planning the fenestration using a semi-automated centerline. The Endurant stent was planned to land flush at the aortic bifurcation.

View Article and Find Full Text PDF

The management of multiple intracranial aneurysms presents significant clinical challenges, particularly when complicated by underlying conditions such as cerebral atherosclerosis. This case report highlights the successful treatment of a 66-year-old female diagnosed with three intracranial aneurysms located in the right middle cerebral artery (MCA), pericallosal artery, and M2 segment. The patient also had a history of systemic atherosclerosis and right-sided breast cancer, factors that increased the complexity of surgical intervention.

View Article and Find Full Text PDF

Background And Purpose: This animal study was designed to evaluate in vivo the acute and short-term safety and efficacy of the new Artisse intrasaccular device (ISD) for aneurysm occlusion and to gain knowledge about the behavior in the aneurysms.

Materials And Methods: The device was implanted in 7 white New Zealand rabbits with bifurcation aneurysms. Immediate and 90-day angiographic follow-up as well as histologic and scanning electron microscope imaging were evaluated.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!