Background: We developed an extracorporeal liver perfusion (ECLP) system as a liver-assist device. In this study, we evaluated the safety of the ECLP using human decay accelerating factor (hDAF) transgenic porcine livers in healthy baboons.
Methods: Livers were isolated from five hDAF transgenic pigs and five nontransgenic pigs for the ECLP. Ten cross-circulations between the ECLP and healthy baboons were performed without immunosuppressive agents. Cross-circulation was discontinued in any of the following circumstances: elevated hepatic arterial (>200 mm Hg) or portal (>60 mm Hg) perfusion pressure, massive exudate from the graft liver, mild macroscopic hemolysis, thrombocytopenia, or 24-hr well-conditioned cross-circulation.
Results: The cross-circulations with nontransgenic porcine livers were discontinued at 4.4+/-1.2 hr (mean+/-standard deviation) because of high perfusion pressure (n=2) or hemolysis (n=3). Three cross-circulations with hDAF transgenic porcine livers were performed for 24 hr; the other two cross-circulations were discontinued at 13 and 17 hr because of massive exudate and thrombocytopenia, respectively. The duration was 20.4+/-5.1 hr. Deposition of membrane attack complex in the hDAF transgenic porcine liver was less than that in the nontransgenic liver, although immunoglobulin-M deposition was comparable. The porcine livers showed no apparent interlobular bleeding or lobular necrosis. All porcine livers maintained bile production during the cross-circulation. No baboons showed any serious complications after the cross-circulation.
Conclusion: The hDAF transgenic porcine liver reduced complement activation in xenoperfusion with healthy nonhuman primate blood and led to extended duration of cross-circulation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/01.TP.0000063221.65123.49 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!