A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Analytical evaluation of hemoglobin A(1c) dual kit assay on Bio-Rad Variant II: an automated HPLC hemoglobin analyzer for the management of diabetic patients. | LitMetric

Objectives: To evaluate the analytical performance of the Bio-Rad Variant II HbA(1c) dual kit assay.

Design And Methods: Precision, carryover, linearity and analytical range were investigated. 139 patients' HbA(1c) results analyzed by the Variant II were compared to the Variant I method. 49 blood samples analyzed by the Variant II at Toronto Medical Laboratories (TML) were compared to the Variant II at Hospital for Sick Children (HSC).

Results: Total imprecision was less than 2% for the Variant II assay. The method had a wide analytical range with no carryover. HbA(1c) results were not changed after switching back and forth from the beta thalassemia to HbA(1c) assay. The Variant II showed an average of 0.0027 negative bias compared to the Variant I method. There was an average of 0.0020 negative bias for HbA(1c) results on the Variant II at TML compared to the Variant II at HSC.

Conclusions: HbA(1c) analysis on the Variant II HbA(1c) dual kit is a relatively fast and reproducible method.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0009-9120(03)00013-4DOI Listing

Publication Analysis

Top Keywords

compared variant
16
dual kit
12
variant
12
bio-rad variant
8
variant hba1c
8
hba1c dual
8
analytical range
8
analyzed variant
8
variant method
8
tml compared
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!