Purpose: To report a new technique for safely and quickly removing a displaced capsular tension ring from the vitreous cavity.
Design: Two interventional case reports.
Participants: The authors retrospectively reviewed the charts of two patients with displaced capsular tension rings (CTRs).
Intervention: Surgical removal of the displaced CTRs was performed in two patients.
Main Outcome Measures: Visual and anatomic outcomes.
Results: The CTRs were removed surgically, in case 1 by cutting the CTR into two pieces before removal and in case 2 by using the CTR injector to remove the CTR in one piece through a sclerotomy site. Both patients had good visual and anatomic outcomes.
Conclusions: The described technique of removing a displaced CTR in one piece through a sclerotomy site using the CTR injector provides a safe and efficient method of CTR removal. Cutting the CTR into two or more pieces for removal is not recommended.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/S0161-6420(03)00332-4 | DOI Listing |
Indian J Ophthalmol
January 2025
Dr. Rajendra Prasad Centre for Ophthalmic Sciences, AIIMS, New Delhi, India.
Scleral-fixated intraocular lens (SFIOL) is a widely used technique for IOL implantation in patients where capsular support is insufficient. Most surgeons have shifted away from sutured to sutureless SFIOL techniques where haptics of a multifocal IOL are inserted in scleral tunnels/flaps. Large-scale publications have shown wide variation in the refractive status of eyes post-SFIOL even in the best of the hands.
View Article and Find Full Text PDFInt J Ophthalmol
December 2024
School of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou 325027, Zhejiang Province, China.
Aim: To present a technique of transcapsular scleral fixation of the standard capsular tension ring (CTR) through equatorial capsulotomy and in-the-bag intraocular lens (IOL) implantation in subluxated lenses.
Methods: This retrospective consecutive case series included patients with subluxated lenses by more than 180 degrees who underwent lens extraction, transcapsular scleral fixation of the standard CTR through equatorial capsulotomy, in-the-bag IOL implantation and with at least 6mo follow-up. Preoperative and postoperative best corrected visual acuity (BCVA), intraocular pressure (IOP), complications, and postoperative IOL tilt and decentration were recorded.
JBJS Essent Surg Tech
December 2024
Sports Medicine Center, Department of Orthopaedics, Massachusetts General Hospital, Mass General Brigham, Boston, Massachusetts.
Background: Whereas uncomplicated labral tears with preserved fibers can be effectively treated with use of labral repair techniques, complex tears and hypoplastic labra require labral reconstruction. Standard reconstruction techniques feature grafted tissue that is added to existing, deficient tissue or that is utilized to replace a hypoplastic labrum entirely. However, such approaches utilizing allografts or remote autografts are limited because they often necessitate extensive debridement of the existing labrum to prepare a site for graft implantation, an approach that can damage and devascularize the chondrolabral junction.
View Article and Find Full Text PDFCureus
November 2024
Department of Ophthalmology, Shimane University Faculty of Medicine, Izumo, JPN.
We report a case of acute angle closure secondary to pupillary block caused by a dislocated intraocular lens (IOL)-capsular tension ring (CTR) complex. A 68-year-old woman, who had undergone cataract surgery 28 months earlier, presented with acute right eye pain and blurred vision. Examination revealed elevated intraocular pressure (IOP) of 80 mmHg, corneal edema, and anterior chamber shallowing, with anterior displacement of the IOL-CTR complex observed on anterior-segment optical coherence tomography.
View Article and Find Full Text PDFJ Shoulder Elbow Surg
November 2024
Department of Orthopaedic Surgery, Kurume University Medical Center, Fukuoka, Japan.
Background: Although arthroscopic Bankart repair for shoulder instability after a traumatic shoulder dislocation is a standard procedure, return-to-play rates for overhead-throwing athletes with shoulder instability on the throwing side have been reported to be lower than those in non-overhead athletes or in non-throwing shoulders. A recent technical report showed that the dynamic anterior glenohumeral capsular ligament tensioning (DAGHT) procedure in abducted external rotation, which mimics the late cocking phase of the throwing motion during surgery, may provide optimal tensioning of the anterior glenohumeral ligament. This study compared clinical outcomes and return to play after arthroscopic Bankart repair between DAGHT and a conventional procedure for overhead-throwing athletes with traumatic dislocation on the throwing side.