Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: We prospectively assessed the accuracy of 3-dimensional (3-D) volume rendered computerized tomography (CT) and conventional renal arteriography to visualize renovascular anatomy in patients undergoing laparoscopic donor nephrectomy.
Materials And Methods: A total of 60 consecutive patients undergoing laparoscopic donor nephrectomy (left side in 46 and right side in 14) prospectively underwent 3-D CT and renal angiography. A short videotape of 3-D CT was prepared using volume rendering software that demonstrated the anatomical location, number, anomalies and spatial interrelationships of the renal arteries and veins. These 3-D videotapes and arteriogram findings were directly correlated with intraoperative surgical findings at laparoscopy and during ex vivo bench preparation of the harvested kidney. The perceived intraoperative value of 3D-CT to delineate renovascular anatomical detail was scored subjectively by the laparoscopic surgeon for each case on a 10-point scale of 0--completely inaccurate to 10--completely accurate.
Results: There were no complications related to the 3-D CT protocol and volume rendering was successful in all patients. Three-D CT accurately identified the number of renal arteries in 59 patients (98%). In 1 patient with 3 renal arteries 3-D CT and arteriogram each identified only 2. In the 46 patients undergoing left donor nephrectomy 3-D CT accurately identified the number of veins and venous anomalies in 45 (98%), including 2 with a circumaortic left renal vein. Another case of circumaortic vein was misdiagnosed as 2 renal veins. On the right side in 14 patients 3-D CT accurately identified the renal veins in 13 (94%) and missed 1 vein in a patient with 2 renal veins. Angiography correctly identified the number of renal veins in only 52 cases (87%). Furthermore, it misdiagnosed all 3 cases of circumaortic left renal vein. The laparoscopic surgeon believed that 3-D CT accurately identified the location and anatomical interrelationship of the renal vessels with precision. Mean subjective score +/- SEM was 8.5 +/- 1 for the arterial system, 8.6 +/- 1.1 for the venous system and 9.2 +/- 0.5 for any vascular anomalies.
Conclusions: Three-D CT accurately identifies renal vascular anatomy in a manner that may facilitate renal hilar dissection during laparoscopic donor nephrectomy, especially during the initial surgeon experience. This imaging modality integrates essential information from angiography, venography and excretory urography into a single study, and it can obviate the need for more invasive vascular imaging in most cases.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/01.ju.0000068039.79654.d3 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!