Background: The aim of this study was to clarify the value of three-dimensional computed-tomography (3D-CT) volumetry for size matching in living-donor liver transplantation (LDLT).

Methods: 3D-CT volumetry was applied to 25 donors who underwent hepatectomy for a living relative needing an orthotopic liver transplantation. Fifteen patients underwent extended left lobectomy, one patient an extended left lateral lobectomy, and nine patients right lobectomy. 3D-CT imaging was performed with the workstation ZIO M900 (Zio Software Inc., Tokyo, Japan). The estimated volume of the grafts in two-dimensional (2D) and 3D images were compared, and an error ratio was calculated.

Results: 3D-CT imaging revealed the anatomy of the hepatic vein bifurcation and the shape of the graft. The error ratio was 12.8+/-2.3% in 3D, compared with 19.4+/-2.5% in 2D. As such, 3D-CT volumetry appears to be more exact than conventional 2D-CT volumetry, but volumetry by 3D-CT still produces an error ratio of approximately 13%. The weight transition of the rats' livers under preservation in University of Wisconsin (UW) solution indicated that the graft volume seems to decrease during perfusion with UW solution. Mismatch of the cutting line and volume reduction by dehydration (approximately 5% reduction 1 hour after perfusion) seems to cause the error in 3D-CT volumetry.

Conclusions: Three-dimensional CT volumetry is useful for size matching in cases of living-related orthotopic liver transplantation.

Download full-text PDF

Source
http://dx.doi.org/10.1097/01.TP.0000053755.08825.12DOI Listing

Publication Analysis

Top Keywords

3d-ct volumetry
12
liver transplantation
12
error ratio
12
volumetry size
8
size matching
8
orthotopic liver
8
extended left
8
3d-ct imaging
8
volumetry
7
3d-ct
7

Similar Publications

Background: Several studies found that early pancreatic atrophy detected by computed tomography (CT) within 6 months was associated with a high incidence of diabetes in patients with type-1 autoimmune pancreatitis (AIP) receiving steroid therapy; however, no long-term follow-up studies have been performed.

Aim: To investigate pancreatic volume (PV) changes using three dimensional (3D)-CT volumetry and their relationship with IgG4 and diabetes in patients with AIP.

Methods: This retrospective study included 33 patients with type-1 AIP receiving steroid therapy.

View Article and Find Full Text PDF

The aim of this study was to evaluate the clinical outcomes of linear and orbital volume measurements in severe orbital trauma. Patients with severe orbital trauma that involved more than two walls and entailed a marked degree of comminution were included in this retrospective analysis. However, patients with incomplete clinical records and a simple blowout or zygmatico-orbital fractures were excluded.

View Article and Find Full Text PDF
Article Synopsis
  • * Pouch resizing using a MiniMIZER® Gastric Ring can help manage weight regain caused by pouch dilatation and requires thorough pre-surgical evaluations, including endoscopies and imaging studies.
  • * The article outlines the standardized procedures for pouch resizing, discusses indications for revisional surgery, pre-surgical assessments, and describes the surgical process and post-operative care necessary for successful outcomes.
View Article and Find Full Text PDF

Objectives: This study examined whether a resected lung lobe can affect the accuracy of postoperative forced expiratory volume in 1 s (FEV1) predicted using the subsegment counting method and three-dimensional computed tomography (3D-CT) volumetry.

Methods: Overall, 125 patients who underwent lobectomy through video-assisted thoracic surgery were enrolled in this retrospective study. Pulmonary function tests were performed preoperatively and postoperatively at 3 months.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!