A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The World Health Organization's External Quality Assurance System Proficiency Testing Program has improved the accuracy of antimicrobial susceptibility testing and reporting among participating laboratories using NCCLS methods. | LitMetric

A total of 150 laboratories in 33 countries that followed the NCCLS testing procedures participated in the World Health Organization's External Quality Assurance System for Antimicrobial Susceptibility Testing (EQAS-AST) from January 1998 through March 2001. Laboratories tested seven bacterial isolates for antimicrobial resistance and reported the results to the Centers for Disease Control and Prevention (CDC) in Atlanta, Ga. The results were compared to the results generated at the CDC with the NCCLS broth microdilution and disk diffusion reference methods. Although there were few testing errors with Salmonella enterica subsp. enterica serovar Enteritidis, drugs that are not appropriate for therapy of Salmonella infections were tested and reported by 136 (91%) of 150 laboratories. In addition, 29 (20%) of 150 laboratories used the Staphylococcus aureus breakpoints to report oxacillin results for Staphylococcus saprophyticus. For a vanB-containing Enterococcus faecalis strain, 124 (83%) of 150 laboratories correctly reported vancomycin results that were +/-1 doubling dilution from the reference MIC or +/-3 mm from the reference disk diffusion result. Of the laboratories that tested Streptococcus agalactiae by disk diffusion, 17% reported nonsusceptible results for penicillin in error. While 110 laboratories (73%) tested the S. pneumoniae challenge isolate against a fluoroquinolone, 83% tested it against ciprofloxacin, for which there are no NCCLS interpretive criteria. Ten of 12 laboratories testing levofloxacin and 4 of 4 laboratories testing ofloxacin by an MIC method correctly reported resistant results for the isolate. Feedback letters sent to participating laboratories highlighted areas of susceptibility testing in individual laboratories that needed improvement. The positive impact of the feedback letters and the overall effectiveness of the EQAS program were documented in repeat testing challenges with pneumococci and staphylococci. The 31 and 19% increases in the numbers of laboratories using appropriate testing methods for pneumococci and staphylococci, respectively, in 2000 versus 1998 indicate that laboratory performance is improving.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC156569PMC
http://dx.doi.org/10.1128/JCM.41.6.2372-2377.2003DOI Listing

Publication Analysis

Top Keywords

150 laboratories
16
laboratories
13
susceptibility testing
12
disk diffusion
12
testing
10
health organization's
8
organization's external
8
external quality
8
quality assurance
8
assurance system
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!