Near-infrared (NIR) optical tomography provide estimates of the internal distribution of optical absorption and transport scattering from boundary measurement of light propagation within biological tissue. Although this is a truly three-dimensional (3D) imaging problem, most research to date has concentrated on two-dimensional modeling and image reconstruction. More recently, 3D imaging algorithms are demonstrating better estimation of the light propagation within the imaging region and are providing the basis of more accurate image construction algorithms. As 3D methods emerge, it will become increasingly important to evaluate their resolution, contrast, and localization of optical property heterogeneity. We present a concise study of 3D reconstructed resolution of a small, low-contrast, absorbing and scattering anomaly as it is placed in different locations within a cylindrical phantom. The object is an 8-mm-diameter cylinder, which represents a typical small target that needs to be resolved in NIR mammographic imaging. The best resolution and contrast is observed when the object is located near the periphery of the imaging region (12-22 mm from the edge) and is also positioned within the multiple measurement planes, with the most accurate results seen for the scatter image when the anomaly is at 17 mm from the edge. Furthermore, the accuracy of quantitative imaging is increased to almost 100% of the target values when a priori information regarding the internal structure of imaging domain is utilized.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/ao.42.003117 | DOI Listing |
Eye (Lond)
January 2025
Department of Ophthalmology, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA.
Purpose: To utilize optical coherence tomography (OCT) and SS-OCT angiography (SS-OCTA) for quantifying morphological changes seen in eyes with recalcitrant neovascular age-related macular degeneration (nAMD) transitioned to intravitreal faricimab injections during the manufacturer's recommended induction phase of treatment.
Methods: Fifty-four treatment-recalcitrant patients (60 eyes) were recruited. OCT and SS-OCTA images were obtained at 0 and 3 months.
Eye (Lond)
January 2025
Division of Clinical Neuroscience, Department of Ophthalmology, University of Nottingham, Nottingham, UK.
Background/objectives: Anterior segment optical Coherence Tomography (AS-OCT) is used extensively in imaging the cornea in health and disease. Our objective was to analyse and monitor corneal vascularisation (CVas) through the corresponding back-shadows visible on AS-OCT.
Subjects/methods: AS-OCT scans were obtained from 26 consecutive patients (eyes) with CVas of different aetiologies.
Sci Rep
January 2025
Mallinckrodt Institute of Radiology, Washington University School of Medicine, 4515 McKinley Ave., St. Louis, MO, 63110, USA.
Functional magnetic resonance imaging (fMRI) has dramatically advanced non-invasive human brain mapping and decoding. Functional near-infrared spectroscopy (fNIRS) and high-density diffuse optical tomography (HD-DOT) non-invasively measure blood oxygen fluctuations related to brain activity, like fMRI, at the brain surface, using more-lightweight equipment that circumvents ergonomic and logistical limitations of fMRI. HD-DOT grids have smaller inter-optode spacing (~ 13 mm) than sparse fNIRS (~ 30 mm) and therefore provide higher image quality, with spatial resolution ~ 1/2 that of fMRI, when using the several source-detector distances (13-40 mm) afforded by the HD-DOT grid.
View Article and Find Full Text PDFJ AAPOS
January 2025
University of Health Sciences, Department of Ophthalmology, Başakşehir Cam and Sakura City Hospital, Istanbul, Turkey.
Purpose: To use swept-source optical coherence tomography angiography (SS-OCTA) to investigate the alterations in retinal vascular density (VD) in patients presenting with congenital unilateral trochlear nerve palsy.
Methods: The medical records of patients diagnosed with congenital unilateral trochlear nerve palsy and those of a healthy control group were reviewed retrospectively. Comprehensive ocular examinations and SS-OCTA imaging were conducted.
Am J Cardiol
January 2025
Department of Cardiovascular Medicine, Osaka University Graduate School of Medicine, Suita, Japan.
A dual-therapy sirolimus-eluting and CD34+ antibody-coated Combo Stent (DTS) has been developed to enhance endothelization and capture endothelial progenitor cells; however, vessel responses following DTS implantation remain unclear. Therefore, we evaluated early- and mid-term intravascular characteristics of DTS using intravascular imaging modalities. This multicenter, prospective, observational study enrolled 88 patients (95 lesions) who underwent DTS (43 patients, 48 lesions) or sirolimus-eluting Orsiro stent (SES, 45 patients, 47 lesions) implantation.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!