A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Digital slide and virtual microscopy based routine and telepathology evaluation of routine gastrointestinal biopsy specimens. | LitMetric

AI Article Synopsis

  • The study evaluates a new digital slide and virtual microscope system compared to traditional optical microscopy for examining gastrointestinal biopsy specimens.
  • Analysis included scanning gastric and colon biopsy samples using a computer-controlled microscope, resulting in a high concordance rate between the two methods in diagnosing cases.
  • The findings suggest that while both methods are reliable, the digital system offers advantages for remote evaluation, indicating potential use in histology labs and teleconsultation with further development.

Article Abstract

Aims: To evaluate a recently developed digital slide and virtual microscope system, and to compare this method with optical microscopy on routine gastrointestinal biopsy specimens in both local and remote access modes.

Methods: A fully computer controlled commercial microscope was used. The scanning program included object detection, autofocus, and image compression algorithms. The overall hard disk space for a gastric biopsy was between 30 and 50 MB and the scanning time was between 20 and 40 minutes. Haematoxylin and eosin stained routine gastric (61) and colon (42) biopsy specimens were selected, scanned, and evaluated by two specialists on an optical (OM) and virtual microscope (VM).

Results: The overall concordance of VM and OM with the consensus diagnosis was 95.1% and 97%, respectively. Clinically important concordance was 96.1% and 98% for VM and OM, respectively. The two methods showed concordance in 92% of cases and clinically important concordance in 94.1% of cases. The reasons for discordance were image quality (one case), interpretation difference (three cases), and insufficient clinical information (three cases). Remote evaluation of the digital slides through the Internet has the advantages of the previously used static and dynamic telepathology methods.

Conclusions: Diagnostic concordance was found between OM and VM. The digital slide and the virtual microscope can be alternative techniques in the computerisation of the histology laboratory and in teleconsultation services after further evaluation of time and storage constraints.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1769977PMC
http://dx.doi.org/10.1136/jcp.56.6.433DOI Listing

Publication Analysis

Top Keywords

digital slide
12
slide virtual
12
biopsy specimens
12
virtual microscope
12
routine gastrointestinal
8
gastrointestinal biopsy
8
clinically concordance
8
three cases
8
concordance
5
digital
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!