The measurement of cardiac transmembrane potential changes with voltage sensitive dyes is in increasing use. Detection of these very small fluorescent alterations using large multiplexed arrays, such as charge coupled device (CCD) cameras at high sampling rates, has proven challenging and usually requires significant averaging to improve the signal-to-noise ratio. To minimize the damage of living tissue stained with voltage sensitive dyes, excitation photon exposure must be limited, with the inevitable consequence of diminishing the fluorescence that is generated. State-of-the-art high frame rate CCD cameras have read noise levels in the 5-10 e(-) rms range, which is at least two orders of magnitude above that required to detect voltage sensitive dye alterations at individual pixels corresponding to 1 mm(2) heart regions illuminated with levels of 100 mW/cm(2) at frame rates approaching 1000 frames/sec. Image intensification is thus required prior to photon quantification. We report here the development of such a data acquisition system using commercially available hardware. Additionally, in the past ten years, a mathematical theory of multiresolution has been developed, and new building blocks called wavelets, allow a signal to be observed at different resolutions. Wavelet analysis also makes possible a new method of extricating signals from noise. We have incorporated spatially adaptive filters based on wavelet denoising of individual pixels to significantly reduce the multiple noise sources present in the acquired data. (c) 1998 American Institute of Physics.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1063/1.166290 | DOI Listing |
Adv Sci (Weinh)
January 2025
Hebei Key Laboratory of Photo-Electricity Information and Materials, College of Physics Science and Technology, Hebei University, Baoding, 071002, P. R. China.
Metal halide perovskites (MHPs) are commonly used in polarization-sensitive photodetectors (PDs) for applications such as polarization imaging, remote sensing, and optical communication. Although various methods exist to adjust the polarization-sensitive photocurrent, a universal and effective approach for continuous control of MHPs' optoelectronic and polarized properties is lacking. A universal strategy to electrically modulate the polarization ratio (PR) of self-powered polarized PDs using the ferro-pyro-phototronic effect (FPPE) in 2D perovskites is presented.
View Article and Find Full Text PDFSmall Methods
January 2025
NEST, Istituto Nanoscienze - CNR and Scuola Normale Superiore, Pisa, I-56127, Italy.
A ground-breaking graphene-based biosensor designed for label-free detection of immunoglobulin M (IgM) achieving a remarkable concentration of 100 zeptomolar (10 m), is reported. The sensor is a two-terminal device and incorporates a millimeter-wide gold interface, bio-functionalized with ≈10 anti-IgM antibodies and capacitively coupled to a bare graphene electrode through a water-soaked paper strip. In this configuration, few affinity binding events trigger a collective electrostatic reorganization of the protein layer, leading to an extended surface potential (SP) shift of the biofunctionalized Au surface.
View Article and Find Full Text PDFBiochem Biophys Res Commun
January 2025
Department of Biopharmaceutics, School of Pharmacy, Tokyo University of Pharmacy and Life Sciences, Tokyo, Japan. Electronic address:
SLC17A3 localized to the apical membrane of the renal proximal tubules has been implicated in the urinary excretion of drugs and endogenous/exogenous metabolites transported into the tubules by OAT1 and OAT3. Because SLC17A3 mediates the facilitated diffusion of organic anions, which requires a sensitive and rapid assay, no system has been established to evaluate its transport activity in mammalian cells. In this study, we demonstrated that the exposure of cells expressing click beetle luciferase (bLuc) and SLC17A3 to D-luciferin produces marked bioluminescence, which enables the evaluation of SLC17A3 function.
View Article and Find Full Text PDFTalanta
January 2025
School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China. Electronic address:
As an emerging ionic sensor with low-voltage operation (<1 V), biocompatibility, and stable operation in aqueous environments, organic electrochemical transistors (OECTs) have attracted significant research interest for various biofluid-related ion detection, where minor ion concentration variations can effectively reflect health or pathology states. However, OECT-based ion sensors are currently limited by restricted device transconductance g and stabilites, which severely hinder their applications in actual ion sensing scenarios. Here, ultra-sensitive multi-ion sensors based on high-performance n-type vertical OECTs (accumulation mode, g = 58 mS) for Na, K, and Ca detection in a practical biofluid (effluent from continuous renal replacement therapy), are demonstrated with high accuracy and stability, which are comparable to conventional Roche method.
View Article and Find Full Text PDFNanotechnology
January 2025
Department of Physics and Astronomy, Uppsala University, Box 516, Uppsala, Uppsala, SE-751 20, SWEDEN.
The growing world population and climate change are key drivers for the increasing pursuit of more efficient and environmentally-safe food production. In this scenario, the large scale use of herbicides demands the development new technologies to control and monitor the application of these compounds, due to their several environmental and health-related problems. Motivated by all these issues, in this work, a hybrid graphene/boron nitride nanopore is explore to detect/identify herbicide molecules (Glyphosate, AMPA, Diuron, and 2,4-D).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!