Thromboresistance of alkali- and heat-treated titanium metal formed with apatite.

J Biomed Mater Res A

Bioceram Division, Kyocera Corporation, Gamo, Shiga 529-1595, Japan.

Published: June 2003

Fibrin deposition and platelet adhesion onto alkali- and heat-treated titanium metal (AH-Ti), alkali- and water-treated titanium metal (Wa-Ti), and alkali- and heat-treated titanium metal formed with apatite (Ap-Ti) in simulated body fluid (SBF) were evaluated by exposure to anticoagulated blood or washed platelet suspension (WPS) under static conditions and subsequent observation with scanning electron microscopy (SEM). The results were compared with those for commercially pure titanium metal (cp-Ti). Thrombus formation on AH-Ti and Wa-Ti, which were exposed to heparinized whole blood for 1 h, was significantly less than that on cp-Ti, on which pronounced depositions of fibrin-erythrocytes and lymphocytes were observed. No thrombus was observed on Ap-Ti, possibly because of a high adsorption of heparin. Morphological change of platelets attached to surfaces via adsorbed plasma proteins was found to a significant extent on AH-Ti and Wa-Ti exposed to WPS. However, there was almost no difference between cp-Ti and Ap-Ti in round morphology of adherent platelets. These findings suggested that Ap-Ti exhibits stronger antithrombogenic characteristics than cp-Ti and other materials examined in heparinized blood.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jbm.a.10494DOI Listing

Publication Analysis

Top Keywords

titanium metal
20
alkali- heat-treated
12
heat-treated titanium
12
metal formed
8
formed apatite
8
ah-ti wa-ti
8
wa-ti exposed
8
heparinized blood
8
titanium
5
metal
5

Similar Publications

Antibiotic residues have become serious health concerns due to the development of antibiotic-resistant bacteria. The treatment of antibiotic pollutants in wastewater is necessary for reducing the issue of antibiotic resistance. In this work, the metal oxide photocatalyst titanium dioxide (TiO) was evaluated for the removal of the tetracycline antibiotic (TC-A) and the deactivation of bacteria (E-B) from wastewater.

View Article and Find Full Text PDF

Cardiovascular diseases (CVDs) remain the leading cause of death worldwide, and the most common form is coronary artery disease (CAD). Treatment options include coronary artery bypass surgery (CABG) or percutaneous heart intervention (PCI), but both have drawbacks. Bare metal stents (BMS) are commonly used to treat CAD; however, they lead to restenosis.

View Article and Find Full Text PDF

One area of technological advancement has been the shift from stainless steel hand tools to nickel-titanium (Ni-Ti) rotary tools. This paper aims to perform an in vitro comparative study to evaluate the efficacy of five endodontic manual and rotary instruments such as Kerr files, Orodeka Plex V, ProTaper Flydent NiTi super files, and ProTaper Flydent NiTi super files in combination with an ultrasonic endodontic E3D Diamantata EMS scaler used for root canal shaping. The following aspects were highlighted: effective removal of smear layer (SL) from the dentinal tubules in the coronal 1/3, middle 1/3, and apical 1/3 of the root canal, appearance of cracks in the dentinal walls by SEM analysis, and highlighting of dentin mineral content and remnant debris by EDX analysis.

View Article and Find Full Text PDF

Carbon fibre reinforced polyetheretherketone (CFR-PEEK) implants have gained interest because of reported biomechanical advantages and radio-lucent properties. The aim of this study was to evaluate the role of CFR-PEEK nails in patients with metastatic bone disease (MBD). We performed a retrospective cohort study evaluating patients with MBD undergoing intramedullary (IM) nailing for prophylaxis or fixation of pathological fractures using CFR- PEEK or titanium implants.

View Article and Find Full Text PDF

Evaluation of frictional wear in a follow-up screw-rod kinematic node in GGS transpedicular stabilization.

Acta Bioeng Biomech

September 2024

Department of Mechanics, Materials and Biomedical Engineering, Faculty of Mechanical Engineering, Wrocław University of Science and Technology, Wrocław, Poland.

: The aim of this study was to evaluate the abrasive wear of the sliding screw-rod joint used in growth guidance system (GGS) stabilizers, allowing for the translation of the screw along the rod during the spinal growth process in a standard and modified system. : The study used single kinematic screw-rod pairs made of titanium alloy Ti6Al4V. Mechanical tests (cyclic loads) simulated the stabilizer's operation under conditions similar to actual use.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!