A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Immunochemical detection of Salmonella group B, D and E using an optical surface plasmon resonance biosensor. | LitMetric

Immunochemical detection of Salmonella group B, D and E using an optical surface plasmon resonance biosensor.

FEMS Microbiol Lett

Department of Public Health and Food Safety, Faculty of Veterinary Medicine, Utrecht University, Utrecht, PO Box 80175, 3508 TD Utrecht, The Netherlands.

Published: May 2003

A surface plasmon resonance biosensor (Biacore) was used to detect Salmonella through antibodies reacting with Salmonella group A, B, D and E (Kauffmann-White typing). In the assay designed, anti-Salmonella antibodies immobilized to the biosensor surface were allowed to bind injected bacteria followed by a pulse with soluble anti-Salmonella immunoglobulins to intensify the signal. No significant interference was found for (mixtures of) 30 non-Salmonella serovars at 10(9) CFU ml(-1). A total of 53 Salmonella serovars were successfully detected at 1 x 10(7) CFU ml(-1), except those of groups C, G, L and P, as expected. The cut-off point was determined with an equicellular mixture of Salmonella enteritidis and Salmonella typhimurium at a final amount of 1.7 x 10(3) CFU per test portion. Although further work is needed to cover the detection of all relevant Salmonella serovars in food-producing animals and food products, this work demonstrates the merits of this alternative biosensor approach in terms of automation, sensitivity, specificity, simple handling and limited hands-on time.

Download full-text PDF

Source
http://dx.doi.org/10.1016/S0378-1097(03)00250-7DOI Listing

Publication Analysis

Top Keywords

salmonella group
8
surface plasmon
8
plasmon resonance
8
resonance biosensor
8
biosensor surface
8
cfu ml-1
8
salmonella serovars
8
salmonella
7
immunochemical detection
4
detection salmonella
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!