Objective: To observe and measure the inside diameter of basicranial arteries, the angulation of main arteries, the three dimensional image characteristic of internal carotid arteries and the anatomical variation of Willis circle.

Methods: The arteries of 30 formalin-fixed adult heads were injected with latex after which the caliber and characteristic of cerebral arteries were observed and measured. The three dimensional image characteristic of internal carotid arteries and its branches were measured using 3D-DSA.

Results: (1) Main artery caliber: origin of internal carotid artery (Left 5.12 +/- 1.48 mm; Right 5.11 +/- 1.42 mm); origin of middle cerebral artery (Left 2.93 +/- 1.44 mm; Right 2.92 +/- 1.46 mm); origin of anterior cerebral artery (Left 2.63 +/- 1.33 mm; Right 2.61 +/- 1.32 mm); origin of vertebral artery (Left 4.37 +/- 1.21 mm; Right 3.22 +/- 1.64 mm); origin of basilar artery (4.45 +/- 1.28 mm); origin of posterior cerebral artery (Left 2.62 +/- 1.36 mm; Right 2.61 +/- 1.22 mm). (2) The angulation of main arteries: C1, 2 of ICA and C4, 5 of ICA (Left 32 +/- 22 degrees; Right 36 +/- 28 degrees ); ICA and ACA (Left 43 +/- 26 degrees; Right 46 +/- 28 degrees). (3) The results show that anatomical and three dimensional image characteristic of internal carotid arteries have no difference (P > 0.05). (4) The anatomical variation of Willis circle: Type O (56.7%); Type A (16.7%); Type P (20.0%); Type AP (6.7%).

Conclusions: It is helpful to measure the inside diameter of basicranial arteries for the selection of various catheter in interventional neuroradiology, to observe the angulation of main arteries and the three dimensional image characteristic of internal carotid arteries for the moulding of various catheter in endovascular therapy and to master the anatomical variation of Willis circle for decreasing complications of endovascular treatment and judging prognosis of cerebrovascular diseases.

Download full-text PDF

Source

Publication Analysis

Top Keywords

three dimensional
20
dimensional image
20
image characteristic
20
internal carotid
20
artery left
20
characteristic internal
16
carotid arteries
16
+/- degrees
16
+/-
15
angulation main
12

Similar Publications

Background: Innovation in crop establishment is crucial for wheat productivity in drought-prone climates. Seedling establishment, the first stage of crop productivity, relies heavily on root and coleoptile system architecture for effective soil water and nutrient acquisition, particularly in regions practicing deep planting. Root phenotyping methods that quickly determine coleoptile lengths are vital for breeding studies.

View Article and Find Full Text PDF

Although the Transformer architecture has established itself as the industry standard for jobs involving natural language processing, it still has few uses in computer vision. In vision, attention is used in conjunction with convolutional networks or to replace individual convolutional network elements while preserving the overall network design. Differences between the two domains, such as significant variations in the scale of visual things and the higher granularity of pixels in images compared to words in the text, make it difficult to transfer Transformer from language to vision.

View Article and Find Full Text PDF

Slopes influenced by multiple faults are prone to large-scale landslides triggered by multi-regional failures. Understanding the failure process and sequence is essential for the sustainable development of mining operations. This paper presents a method combining InSAR monitoring and numerical simulation to analyze the failure processes of slopes affected by multiple faults.

View Article and Find Full Text PDF

Direct printed aligners (DPAs) offer benefits like the ability to vary layer thickness within a single DPA and to 3D print custom-made removable orthodontic appliances. The biocompatibility of appliances made from Tera Harz TA-28 (Graphy Inc., Seoul, South Korea) depends on strict adherence to a standardized production and post-production protocol, including UV curing.

View Article and Find Full Text PDF

The controlled growth of two-dimensional (2D) perovskite atop three-dimensional (3D) perovskite films reduces interfacial recombination and impedes ion migration, thus improving the performance and stability of perovskite solar cells (PSCs). Unfortunately, the random orientation of the spontaneously formed 2D phase atop the pre-deposited 3D perovskite film can deteriorate charge extraction owing to energetic disorder, limiting the maximum attainable efficiency and long-term stability of the PSCs. Here, we introduce a meta-amidinopyridine ligand and the solvent post-dripping step to generate a highly ordered 2D perovskite phase on the surface of a 3D perovskite film.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!