Objective: Conventional end-to-side anastomosis to establish venous outflow for prosthetic arteriovenous grafts often requires operative patch angioplasty within 1 year because of venous stenosis. Rather than conventional venous anastomosis, a modified end-to-side anastomosis at a 15-degree angle with a flow diffuser was constructed. Such diffusers allow decreased flow velocity and increased pressure, inhibiting boundary layer separation.

Methods: Ten brachial artery to axillary vein 6 mm straight se-polytetrafluoroethylene prosthetic arteriovenous grafts were created with this technique. Patients included 6 men and 4 women (mean age, 66.4 years; range, 54-80 years), all with renal failure and a history of diabetes. The degree of stenosis at the venous anastomosis was determined with duplex scanning at intervals of 6 months. Analysis of survival and cumulative primary patency estimates were determined with the Kaplan-Meier method.

Results: Primary cumulative patency estimate of 100% for the modified group at 18 and 24 months was significantly greater than that for age-matched historic control fistulas with the conventional end-to-side anastomosis (n = 20): 18 months, 32%; 24 months, 32% (P <.05). Although venous stenosis could not be quantitated for thrombosed conventional fistulas, modified anastomoses had minimal stenosis at 24 months: mean area reduction, 30% (range, 20%-45%).

Conclusion: Incorporation of a flow diffuser and a 15-degree anastomotic angle significantly increases patency of prosthetic brachial artery to axillary vein grafts.

Download full-text PDF

Source
http://dx.doi.org/10.1067/mva.2003.187DOI Listing

Publication Analysis

Top Keywords

prosthetic arteriovenous
12
arteriovenous grafts
12
end-to-side anastomosis
12
angle flow
8
flow diffuser
8
conventional end-to-side
8
venous anastomosis
8
months 32%
8
anastomosis
5
improved patency
4

Similar Publications

Background: An autologous arteriovenous fistula (AVF) provides an optimal and secure way for managing the condition. An optimal blood supply to hemodialysis is linked to decreased incidence of complications and mortality, as well as reduced expenses. The objective of this research was to evaluate the outcome of people with suboptimal superficial venous system quality or who had exhausted all available arteriovenous fistula options, who received either autologous saphenous vein graft or polytetrafluoroethylene (PTFE) interposition graft as an access for effective hemodialysis.

View Article and Find Full Text PDF

Introduction: The arteriovenous fistula (AVF) is the gold standard access modality for haemodialysis, but due to patient and technical factors, it is prone to stenosis and thrombosis. The trans-radial approach offers multiple unique benefits, but its safety, efficiency and efficacy have not been rigorously studied in the context of the AVF. This study provides a case series of trans-radial AVF procedures, and a systematic review and meta-analysis of existing literature to solidify the role of the trans-radial approach in endovascular AVF surgery.

View Article and Find Full Text PDF

The price of dialysis access: Implications of access type and patient-centric approaches to cost.

J Vasc Access

November 2024

Department of Radiology and Imaging Sciences, Division of Interventional Radiology and Image-Guided Medicine, Emory School of Medicine, Atlanta, GA, USA.

Purpose: This study explores out-of-pocket (OOP) costs for patients and provider reimbursement for dialysis access creation. It aims to illustrate the financial characteristics of four dialysis access modalities to consider in decision-making for clinicians, patients, and payers.

Materials And Methods: Retrospective data from the Merative™ MarketScan Commercial Claims and Encounters Databases from 2017 to 2022 was analyzed for patients who received an arteriovenous fistula (AVF), arteriovenous graft (AVG), peritoneal dialysis catheter (PDC), or percutaneous AVF (pAVF).

View Article and Find Full Text PDF

The management of high flow arteriovenous fistula and possible solutions.

J Vasc Access

October 2024

AUSL Pescara, Interventional Nephrology Unit, Via Fonte Romana, Pescara, Italy.

Background: The development of a high flow rate arteriovenous fistula (AVF) can expose the patient to development of heart failure due to increased cardiac preload and pulmonary hypertension.

Objectives: AVF flow measurement (Qa) is considered a screening tool for AVF surveillance, aiming to evaluate the access dysfunction and prevent complications, like a non-maturation, suspected stenosis, high-flow AVF, and distal ischemia. In the upper arm AVF, a high Qa may develops, which can expose the patient to the risk of high-output heart failure and ischemia.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!