In-patient comparison of immediately loaded and non-loaded implants within 6 months.

Clin Oral Implants Res

Department of Prosthetic Dentistry and Christof Pertl, School of Dental Medicine, Karl-Franzens-University Graz, Austria.

Published: June 2003

According to the Brånemark protocol, a stress-free healing period is one of the most emphasised requirements for implant integration. Recent studies have encouraged a progressive shortening of the healing period and immediate loading has been proposed for the edentulous mandible. This prospective study evaluated the clinical outcomes of 14 immediately loaded FRIALIT-2(R) implants compared with 28 non-loaded controls in an in-patient study. The results were based on clinical stability and on changes of bone level from implant placement to abutment connection 6 months after insertion. In the course of our investigation, seven patients with edentulous mandibles have been treated with 43 implants following an immediate-loading protocol. Six FRIALIT-2(R) implants were placed in the interforaminal region located at positions 34, 33, 32, 42, 43, 44. Bone level in relation to implant margin was measured and recorded. In order to obtain an in-patient comparison of immediately loaded and non-loaded implants, the ones at 33 and 43 were chosen to be immediately loaded by a Dolder-bar retained overdenture. The implants in position 32, 34, 42 and 44 were covered and left to heal. After a healing period of 6 months, second stage surgery was carried out. The clinical criteria to be checked at this point were survival, Periotest values and marginal bone level at the loaded and non-loaded implants. The mean Periotest value was -2.7 for the loaded and -5.6 for the non-loaded implants. The Mann-Whitney U-test showed that the difference was highly significant (P < 0.001). The mean bone level changes at prosthetic delivery were 0.9 mm resorption for the loaded implants and 0.33 mm for non-loaded implants. The difference was highly significant (P < 0.001). No implant failures were observed up to the prosthetic restoration 6 months post insertion. The results of this investigation allowed for direct comparison of implant survival and clinical results between immediately loaded implants and standard implants. Clinical bone changes at the 6-month evaluation demonstrated significantly higher crestal resorption around loaded implants. This fact was confirmed by higher median Periotest values (-3 vs. -6) of immediately loaded implants. According to the outcome of this study, immediate loading of two interforaminal implants with a Dolder-bar resulted in an intimate bone apposition comparable with implants with submerged healing. Nevertheless, the coronal bone level as well as clinical stability (PTV) were significantly lower in the case of the immediately loaded implants. Future studies will be necessary to evaluate marginal bone resorption, Periotest values and clinical success rates of mandibular immediately loaded implants in the long-term.

Download full-text PDF

Source
http://dx.doi.org/10.1034/j.1600-0501.2003.140304.xDOI Listing

Publication Analysis

Top Keywords

loaded implants
24
non-loaded implants
20
bone level
20
implants
18
loaded
12
loaded non-loaded
12
healing period
12
periotest values
12
in-patient comparison
8
comparison loaded
8

Similar Publications

Purpose: Investigating high performance thermoplastic polymers as substitutes to titanium alloy, in fabrication of implants and attachments to support mandibular overdenture, aiming to overcome stress shielding effect of titanium alloy implants. AIM OF STUDY: Assessment of stress distribution in polymeric prosthetic components and bone around polymeric implants, in case of implant-supported mandibular overdenture.

Materials And Methods: 3D finite element model was established for mandibular overdenture, supported bilaterally by two implants at canine region, and retained by two ball attachments.

View Article and Find Full Text PDF

Growth-plate (GP) injures in limbs and other sites can impair GP function and cause deceleration of bone growth, leading to progressive bone lengthening imbalance, deformities and/or physical discomfort, decreased motion and pain. At present, surgical interventions are the only means available to correct these conditions by suppressing the GP activity in the unaffected limb and/or other bones in the ipsilateral region. Here, we aimed to develop a pharmacologic treatment of GP growth imbalance that involves local application of nanoparticles-based controlled release of a selective retinoic acid nuclear receptor gamma (RARγ) agonist drug.

View Article and Find Full Text PDF

Baicalein-loaded porous silk fibroin microspheres modulate the senescence of nucleus pulposus cells through the NF-κB signaling pathway.

Colloids Surf B Biointerfaces

January 2025

The First Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou 510405, PR China; Guangdong Clinical Research Academy of Chinese Medicine, Guangzhou 510130, PR China; Guangzhou University of Chinese Medicine Postdoctoral Research Station, Guangzhou 510130, PR China. Electronic address:

Intervertebral disc degeneration (IVDD), an age-associated degenerative condition, significantly contributes to low back pain, thereby adversely affecting individual health and quality of life, while also imposing a substantial societal burden. Baicalein, a natural flavonoid derived from Scutellaria baicalensis Georgi, demonstrates a range of pharmacological activities, including antioxidant, anti-inflammatory, anti-tumor, and antibacterial properties. This positions it as a promising candidate for the treatment of IVDD through intradiscal drug delivery.

View Article and Find Full Text PDF

Oxidative stress plays a major role in the secondary injury of the spinal cord tissue due to the high lipid content of nervous tissue. In the present study, coaxial nanofibers were loaded with the natural antioxidant pyrroloquinoline quinone (PQQ) and used as an implantable drug-delivery system and a scaffold post-SCI. The obtained data show that the concentration of NO and the activity of inducible nitric oxide synthase (iNOS) were significantly ( < 0.

View Article and Find Full Text PDF

Objective: The aim of this study was to establish a three-dimensional finite element (FE) hydraulic pressure technique model and compare the biomechanical characteristics of the osteotome technique and the hydraulic pressure technique using three-dimensional finite element analysis (FEA).

Methods: Three FE models were created: the hydraulic pressure technique (M1), the osteotome technique with a Ø 1.6-mm osteotome (M2), and the osteotome technique with a Ø 3.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!