Objectives: To evaluate the accuracy of 2 radiographic methods used to assess tibial plateau slope (TPS) in dogs and evaluate effects of film digitization and radiographic beam placement on TPS measurements.
Sample Population: 16 hind limbs from dog cadavers weighing > 20 kg.
Procedures: Radiographs of tibiae were made with the radiographic beam centered over the stifle joint and midshaft of the tibia. Tibiae were collected, the femorotibial contact area was determined, and slope of the medial tibial condyle in relation to the tibial shaft was measured. Radiographs were digitized. Slope of the medial tibial condyle was measured on printed and digitized radiographs read in random order by 6 examiners unaware of anatomic measurements. Three examiners used a conventional measuring technique, and 3 examiners used an alternative measuring technique.
Results: Anatomic measurements were significantly higher than radiographic measurements made by use of the conventional interpretation method but did not differ from radiographic measurements made by use of the alternate method. Measurements from printed radiographs were lower than measurements from digitized radiographs for the 4 most experienced examiners.
Conclusions And Clinical Relevance: Measurements made by use of a line tangential to the cranial, linear portion of the medial tibial condyle at the femorotibial contact point were accurate measurements of the anatomic TPS. Measurements made by use of the conventional TPS measurement method underestimated the anatomic TPS. Measurements made on digitized radiographs were typically more accurate than measurements made on printed radiographs.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.2460/ajvr.2003.64.586 | DOI Listing |
J Exp Orthop
January 2025
Department of Orthopaedic Surgery and Trauma University Center of Montpellier, University of Montpellier Montpellier France.
Purpose: Gap-balanced total knee arthroplasty (TKA) technique relies on initial ligament evaluation, particularly in patient-specific implantation using computer-assisted technologies. This cadaveric study aimed to compare the reproducibility and reliability of medial and lateral gap measurements between manual stress testing and dynamic ligament balancer.
Methods: Initial gap acquisitions were assessed from eight cadaveric knees (four specimens) during the same navigated TKA procedure by five differently skilled surgeons (three seniors and two juniors).
SICOT J
January 2025
Department of Orthopaedics, School of Medicine, Jichi Medical University, Shimotsuke, Japan.
Purpose: To clarify the location of the popliteal artery (PA) is relative to the tibial osteotomy plane in patients with medial and lateral unicompartmental knee osteoarthritis (KOA) undergoing UKA.
Methods: Preoperative MRI and postoperative radiographs obtained from 50 patients with unicompartmental KOA who underwent fixed-bearing UKA were analyzed. The amount of tibial resection was determined from the surgical records, and a line was drawn parallel to the tibial posterior tilt angle on the sagittal MR image to create a virtual tibial cut line.
Asia Pac J Sports Med Arthrosc Rehabil Technol
January 2025
Chinese University of Hong Kong, Hong Kong SAR, China.
This technical note explores the novel use of an imageless robotic surgical system for simultaneous unicompartmental knee arthroplasty (UKA) and anterior cruciate ligament reconstruction (ACLR). Knee osteoarthritis (OA) and anterior cruciate ligament (ACL) insufficiency are common conditions that traditionally require separate management. The integration of robotic assistance offers enhanced precision in surgical procedures, addressing both medial compartment OA and ACL insufficiency in a single operation.
View Article and Find Full Text PDFJ Orthop
July 2025
MBBS, FRACS, FAOthA, Consultant Orthopaedic Surgeon, Melbourne Orthopaedic Group, Melbourne, Victoria, Australia.
Background: A contemporary trend favours a restricted kinematic alignment (rKA) strategy, incorporating safe boundaries to restore a variable percentage of a patient's natural alignment.This study aims to compare preoperative and postoperative coronal plane knee alignment (CPAK) in patients undergoing bilateral TKA with SAIPH implants (MatOrtho, UK). The concept was to control the implant (same prosthesis both sides), patient (bilateral model) and assess what effect any surgical alteration in alignment had on patient's outcomes measured by patient-reported outcome measures (PROMS) and patient satisfaction.
View Article and Find Full Text PDFJ Orthop Case Rep
January 2025
Department of Orthopaedic Surgery, Murup Hospital, Changwon, South Korea.
Introduction: Medial open wedge-high tibial osteotomy (MOW-HTO) is a standard procedure for treating moderate varus arthritis in active adults. The reason for its popularity is having lesser complications than other types of HTO. However, it is not devoid of challenges.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!