The evaluation of new techniques for 2-D and 3-D intravascular ultrasound (US) imaging (IVUS) often requires the use of a pulsating coronary phantom. This study describes the design, construction and evaluation of a phantom simulating the pulsation of a human coronary artery for IVUS studies. Polyvinyl alcohol (PVA) cryogel was used as a tissue mimic for the coronary vessel, which was incorporated in a custom-built assembly. The phantom was programmed to pulsate under servomotor control, to model the pulsation of a normal coronary artery and 2-D IVUS images were obtained using an IVUS imaging catheter. To evaluate the performance of the phantom, the lumen area variation of the phantom was determined and compared with the programmed pulsation waveforms. Our results showed that phantom pulsation correlated well with the programmed pulsation waveform (r = 0.97). The deviation of the least squares line from the line of identity was calculated to be < 4%.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0301-5629(02)00730-5DOI Listing

Publication Analysis

Top Keywords

pulsating coronary
8
coronary vessel
8
intravascular ultrasound
8
coronary artery
8
programmed pulsation
8
phantom
7
pulsation
5
vessel phantom
4
phantom two-
4
two- three-dimensional
4

Similar Publications

Contrast-enhanced CT is a primary tool in emergency departments for diagnosing acute aortic dissection, demonstrating high sensitivity and specificity. However, artifacts such as streak artifacts can mimic aortic dissection, leading to misdiagnosis. Here, we report a case involving a 21-year-old male who sustained traumatic injuries after a motor vehicle accident.

View Article and Find Full Text PDF

Background: Arteriovenous malformations (AVMs) account for <3% of vascular anomalies. This study aims to present the 10-year experience of a German vascular anomaly center (VAC) with AVMs and evaluate diagnostic imaging for treatment-relevant information for minimally invasive therapy planning.

Material And Methods: A retrospective study including patients from the VAC database with AVMs was conducted.

View Article and Find Full Text PDF

Hepatic pregnancy, an exceedingly rare subtype of abdominal ectopic pregnancy, remains clinically challenging due to its infrequency, diverse presentations, and diagnostic difficulties. We report the clinical course, diagnostic journey and treatment of a woman with a primary hepatic pregnancy. The patient presented with acute pain in the right hypochondrium and vomiting.

View Article and Find Full Text PDF

The stomach has a rich blood supply; for this reason, acute gastric necrosis is a rare clinical condition and needs a high index of suspicion, especially in those patients having no history of an eating disorder and no signs of gastric distension on radiological investigations. We report on a 23-year-old male patient who presented to the emergency department with a one-day history of severe abdominal pain and multiple episodes of vomiting. On examination, his heart rate was 110 beats per minute.

View Article and Find Full Text PDF
Article Synopsis
  • The article describes the creation of the first ultrasound system for continuous monitoring of brain tissue pulsations (BTPs) using transcranial Doppler (TCD) technology.
  • A lightweight, wearable probe called Transcranial Tissue Doppler (TCTD) was developed to measure tissue motion and was tested successfully with existing TCD hardware.
  • The new system, Brain Tissue Velocimetry (Brain TV), can capture BTP data in real-time alongside other vital physiological measurements and shows potential for clinical assessment in healthy and stroke patients.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!