The purpose of this study was to find out if the use of 1.25-mm collimated thin-slice technique helps to detect more small pulmonary lung nodules than the use of 5 mm. A total of 100 patient examinations that allowed a reconstruction of 1.25-mm slice thickness in addition to the standard of 5-mm slices were included in a prospective study. Acquisition technique included four rows of 1-mm slices. Two sets of contiguous images were reconstructed and compared with 1.25- and 5-mm slice thickness, respectively. Two radiologists performed a film-based analysis of the images. The size and the confidence of the seen nodules were reported. We did not perform a histological verification, according to the normal clinical procedure, although it would be optimal regarding research. Statistical analysis was performed by using longitudinal analysis described by Brunner and Langer. In addition, sensitivity, specificity, negative predictive value and positive predictive value were calculated for each reader using the 1.25-mm sections as the gold standard. As an index for concordance the kappa value was used. A value of p<0.05 was regarded as significant. In 37 patients pulmonary nodules were detected. Twenty-four patients showed more than one nodule; among these, 7 patients had disseminated disease and were excluded from the study. Pulmonary nodules larger than 10 mm in size were equally well depicted with both modalities, whereas lesions smaller than 5 mm in size were significantly better depicted with 1.25 mm (p<0.05). Using 1.25 mm as the gold standard, sensitivity for 5-mm reconstruction interval was 88 and 86% for observers A and B, respectively. No false-positive results were reported for 5-mm sections. Interobserver agreement for nodule detection determined for 1.25-mm reconstruction intervals showed a k value of 0.753, indicating a good agreement, and 0.562 for 5-mm reconstruction intervals, indicating a moderate agreement. Brunner and Langer analysis showed significant differences for slice thickness and no significant difference between the observers. Reduced slice thickness demonstrated an improvement of small nodule detection, confidence levels, and interobserver agreement. Application of thin-slice multidetector-row CT may raise the sensitivity for lung nodule detection, although the higher detection rate of smaller nodules has to be evaluated from a clinical perspective and remains problematic about how the detection of small nodules will effect patient outcome.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00330-003-1915-7DOI Listing

Publication Analysis

Top Keywords

slice thickness
12
detection pulmonary
4
pulmonary nodules
4
nodules multislice
4
multislice computed
4
computed tomography
4
tomography improved
4
improved detection
4
detection rate
4
rate reduced
4

Similar Publications

Background: Flail chest (FC) injuries are segmental osseous injuries of the thorax that typically result from high-energy blunt trauma and regularly occur in multiple trauma (MT) patients. FC injuries are associated with paradoxical chest wall movements and, thus, have a high risk of respiratory insufficiency or even death. An increasing number of studies recommend an early surgical stabilization of FC injuries, but a definite trigger that would indicate surgery has, thus far, not been identified.

View Article and Find Full Text PDF

To describe the distribution of jugular bulb position and pneumatization of posterior lip of internal auditory meatus (IAM) in patients with vestibular schwannoma (VS). This retrospective study included 43 patients who had a thin slice (< 2 mm) CT temporal bone for preoperative planning of retrosigmoid approach for excision of VS between March 2011 and March 2021. On computed tomography (CT), high riding jugular bulb was defined by its relationship to IAM and correlated with type of jugular bulb according to Manjila et al.

View Article and Find Full Text PDF

The potential of photon-counting CT for the improved precision of lung nodule radiomics.

Phys Med Biol

January 2025

Department of Radiology, Duke University, Suite 302 Hock Plaza, 2424 Erwin Rd, Durham, North Carolina, 27708-0187, UNITED STATES.

Lung nodule appearance may provide prognostic information, as the presence of spiculation increases the suspicion of a nodule being cancerous. Spiculations can be quantified using morphological radiomics features extracted from CT images. Radiomics features can be affected by the acquisition parameters and scanner technologies; thus, it is essential to identify imaging conditions that provide reliable measurements, particularly for emerging technologies like photon-counting CT.

View Article and Find Full Text PDF

Three-dimensional measurement of the depth of invasion in oral squamous cell carcinoma samples using Lugol's iodine-enhanced micro-computed tomography: an original study.

J Appl Oral Sci

January 2025

Nanjing University, Research Institute of Stomatology, Affiliated Hospital of Medical School, Nanjing Stomatological Hospital, Department of Oral and Maxillofacial Trauma Orthognathic Plastic Surgery, Nanjing, China.

Objectives: Depth of invasion (DOI) in oral squamous cell carcinoma (OSCC) guides treatment and prognosis but lacks three-dimensional (3D) insight. Thus, this study aimed to investigate the feasibility and accuracy of Lugol's iodine-enhanced micro-computed tomography (CT) for the 3D measurement of DOI in OSCC samples.

Methodology: In total, 50 in vitro OSCC samples from Nanjing Stomatological Hospital (July 2022 to January 2024) were subjected to micro-CT imaging with a slice thickness of 50 μm following 3% Lugol iodine staining for 12 h, followed by pathological examination and staining.

View Article and Find Full Text PDF

Introduction The role of the condylar position in the correct functioning of the stomatognathic system has been the center of the study. Using cone-beam computed tomography (CBCT), this study looked at the three-dimensional (3D) position of the condylar bone in patients from Class I, Class II, Division 1, and Division 2. Materials and methods This cross-sectional, retrospective study was conducted using 102 CBCT records, with 34 records allocated to each category of malocclusion classification, such as dentoskeletal Class I, skeletal Class II, and dental Class II, Division 1 and 2.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!