Purpose: The purpose of this study was to develop and validate an animal model of drug disposition in synovial fluid (SF) by comparing microdialysis with arthrocentesis using the anti-arthritic drug methotrexate (MTX).
Methods: Microdialysis probes were calibrated in vitro with the no net flux method using dog synovial fluid. The probes were implanted surgically into the stifle joint space of four dogs and were dialyzed overnight using a portable microinfusion pump. The membrane integrity of the probes was monitored by retrodialysis using an internal standard. After an intravenous bolus of 2.5 mg/kg of MTX, unbound concentrations in synovial fluid, as well as total plasma concentrations, were measured by liquid chromatography tandam mass spectrometer (LC/MS/MS) in samples collected from 0 to 48 h postdose.
Results: The probe membrane remained intact at least 48 h after implantation. The mean probe recovery and unbound fraction of MTX in SF were 46.8% and 44.8%, respectively. The unbound fraction of MTX was 44% in synovial fluid. MTX penetrated into the joint space rapidly, with maximal concentrations of 6.6 microM reached at approximately 1 h postdose. The unbound MTX area under the curve in SF was approximately 40% of the total area under the curve in plasma. These data agree well with the previous data obtained for MTX using arthrocentesis.
Conclusion: In contrast with arthrocentesis, microdialysis enables the collection of multiple serial SF samples from individual animals with minimal trauma and potential blood contamination. This animal model should prove valuable for studying the disposition of new antiarthritis compounds or biomarkers in SF.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1023/a:1023246832321 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!