A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The inhalation manager: a new computer-based device to assess inhalation technique and drug delivery to the patient. | LitMetric

The rational choice of an inhalation device is a cornerstone in the effective management of asthma and COPD. In this publication, we describe the development of a new system, the Inhalation Manager, which, for the first time, offers the possibility to assess the entire inhalation maneuver of patients using original devices under everyday conditions. So far the Inhalation Manager allows the measurement of inspiratory maneuvers of patients through placebo inhalation devices of the most common breath-actuated CFC-free inhalers in the market for the three main glucocorticosteroids Budesonide [Turbohaler (TH), dry powder inhaler (DPI)], Beclomethasone dipropionate [Autohaler (AH), breath-actuated pressurized metered dose inhaler (pMDI)], and Fluticasone propionate [Diskus (DI), DPI] by means of a pneumotachometer. In addition, it allows allocation of the individual maneuver to the expected drug delivery values (mass output and particle size distribution) of these three devices. In a field trial, the inhalation technique of 628 (TH), 794 (AH), and 795 (DI) patients, respectively, was tested in 72 pulmonologist practices with the Inhalation Manager. For patients in the 18-59-year-old group, the Inhalation Manager detected the following percentages needing improvement: 1.5% for the Autohaler device, 16.7% for the Diskus, and 38.9% for the Turbohaler. In the 60-99-year-old group, percentages needing improvement were 1.5%, 31.5%, and 66.1% for the Autohaler, Diskus, and Turbohaler, respectively. Therefore, the Inhalation Manager could become an essential tool in asthma management by finding the most suitable inhaler for an individual patient and by training the optimal inhalation technique.

Download full-text PDF

Source
http://dx.doi.org/10.1089/089426803764928329DOI Listing

Publication Analysis

Top Keywords

inhalation manager
24
inhalation
12
inhalation technique
12
drug delivery
8
percentages needing
8
needing improvement
8
improvement 15%
8
manager
5
manager computer-based
4
computer-based device
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!