A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Highly sensitive determination of a polymeric hindered amine light stabilizer in polypropylene by reactive thermal desorption-gas chromatography using nitrogen-specific detection. | LitMetric

Highly sensitive and specific determination of trace amounts of a polymeric hindered amine light stabilizer (HALS) in polypropylene (PP) materials could be established by improving reactive thermal desorption-gas chromatography (RTD-GC) in the presence of an organic alkali, tetramethylammonium hydroxide. By using nitrogen-phosphorus detection, highly selective detection of the HALS-related components was attained. In addition, the use of a polar poly(ethylene glycol) separation column alleviated the adsorption of minor specific pyrolysis products. This modified RTD-GC method allowed the determination of the polymeric HALS (Mr 1900) in PP even for trace concentrations between 100 and 500 ppm, through observing selectively the characteristic products containing a tetramethylpiperidine moiety, which had been impossible to detect under the previous RTD-GC conditions using a non-polar separation column and conventional flame ionization detection.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0021-9673(03)00323-6DOI Listing

Publication Analysis

Top Keywords

highly sensitive
8
determination polymeric
8
polymeric hindered
8
hindered amine
8
amine light
8
light stabilizer
8
reactive thermal
8
thermal desorption-gas
8
desorption-gas chromatography
8
detection highly
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!