The basic mechanism of dental amalgam corrosion has been thoroughly studied during the last 50 years by various experimental techniques, most often carried out in vitro. Electrochemical methods were extensively employed, and it was recognized that a gradual dealloying of the more electroactive components, Zn, Sn, and to a lesser extent Cu, contributed to change the surface composition. It is also well known that, in all circumstances, galvanic coupling threatens the longevity of the restoration. Among the patients examined at the hospital attached to the Department of Dental Surgery of the Paris 5 University, the authors observed, in a few exceptional circumstances of defective restorations, a release of liquid metal droplets in the surrounding tissue. These particles were identified as elemental mercury. This unexpected phenomenon was the result of the use of a low-silver-content alloy, combined with an enhanced corrosion process due to galvanic coupling with a silver alloy crown and brass screw-posts. In the described clinical case, the tooth, which had to be extracted, was axially sliced for observation by scanning electron microscopy coupled with elemental analysis by X-ray fluorescence energy dispersive spectroscopy. The observations showed a dramatic corrosion of the amalgam matrix with the formation of porosity even in the bulk of the material. Superposition of the element mappings proved (1) the electrochemical coupling of the amalgam with the silver-based crown, (2) the decalcification of the dentin, and (3) the formation of tin oxychloride precipitates in the matrix porosities and the interfacial gaps. These experimental results corroborate the corrosion mechanisms described hereupon. They support the current national and international recommendations for the dental amalgam formulation and for a rigorous professional practice.
Download full-text PDF |
Source |
---|
Sci Rep
December 2024
School of Computer Science, University of Nottingham, Nottingham, UK.
Robotics holds the potential to streamline the execution of repetitive and dangerous tasks, which are difficult or impossible for a human operator. However, in complex scenarios, such as nuclear waste management or disaster response, full automation often proves unfeasible due to the diverse and intricate nature of tasks, coupled with the unpredictable hazards, and is typically prevented by stringent regulatory frameworks. Consequently, the predominant approach to managing activities in such settings remains human teleoperation.
View Article and Find Full Text PDFBioact Mater
February 2025
Medical School of Chinese PLA, Beijing, 100039, China.
Zn-based biodegradable metals (BMs) are regarded as revolutionary biomaterials for bone implants. However, their clinical application is limited by insufficient mechanical properties, delayed degradation, and overdose-induced Zn toxicity. Herein, innovative multi-material additive manufacturing (MMAM) is deployed to construct a Zn/titanium (Ti) hetero-structured composite.
View Article and Find Full Text PDFMater Horiz
December 2024
MOE Key Laboratory of Material Physics and Chemistry under Extraordinary Conditions, School of Physical Science and Technology, Northwestern Polytechnical University, Xi'an 710072, China.
Interface engineering, by modulating defect distribution and impedance at interfaces and inducing interfacial polarization, has proven to be an effective strategy for optimizing dielectric properties. However, the inherent incompatibility between heterogeneous phases presents a significant challenge in constructing multi-heterointerfaces and understanding how their distribution influences dielectric performance. Herein, we constructed an EGaIn@Ni/NiO/GaO composite structure by employing a low-intensity ultrasound-assisted galvanic replacement reaction followed by high-temperature annealing.
View Article and Find Full Text PDFRSC Adv
December 2024
School of Mechatronic Engineering, Xi'an Technological University No.2 Xuefuzhonglu Road Xi'an 710021 China
In this paper, homogenization heat treatment and laser shock peening (LSP) processes were successfully carried out regulate the microstructure (grain size, residual stress, and element distribution, ) of the AZ31B magnesium alloy substrate surface. Based on the regulated AZ31B magnesium alloy substrate surface, it further explored and analyzed the mechanism and influence pattern of the coupling distribution of grain size and residual stress on the intergranular corrosion susceptibility of the substrate surface. Scanning electron microscopy (SEM) was used to observe the surface morphology, scanning Kelvin probe force microscopy (SKPFM) to observe the surface potential, zero resistance ammeter (ZRA) and scanning vibrating electrode technique (SVET) to measure the galvanic current on the surface, and electrochemical tests were conducted to evaluate its surface corrosion behavior.
View Article and Find Full Text PDFDent Mater
December 2024
Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece.
Purpose: To assess the effect of healthy and inflammatory conditions and the presence of F anions on the galvanic coupling between the root surface and titanium abutments of commercially available titanium implants MATERIALS AND METHODS: Eight pairs of three dental root-abutment couples (BEGO, MIS, NOBEL) were exposed to a neutral (pH=7.4) (HE) and an acidic (pH=4.0) (IN) phosphate buffer solution (PBS) simulating healthy and inflammatory conditions respectively.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!