Objectives: To compare the accuracy of palpation-guided and high frequency ultrasound-guided needle placement in small joints and to develop a technique to obtain synovial fluid from these joints for diagnosis and research.

Methods: The accuracy of needle placement during palpation-guided proximal interphalangeal (PIP) or metacarpophalangeal (MCP) joint injection was assessed. This was compared with the accuracy of ultrasound-guided needle placement. A joint lavage technique was developed to obtain synovial fluid from these joints.

Results: Needle positioning was intra-articular in 59% of palpation-guided injections (6/12 PIP and 4/5 MCP joints). No fluid could be aspirated prior to injection. With ultrasound guidance, initial needle placement was intra-articular in 96% of cases (24/26 PIP and 27/27 MCP joints). Synovial fluid cells were lavaged from 63% of joints (19/25 PIP and 14/27 MCP joints). In only one case was a large effusion seen and this was aspirated directly.

Conclusions: The use of high frequency ultrasound to guide needle placement within a small joint allows for significantly greater accuracy than a palpation-guided approach. When followed by lavage, synovial fluid cells and diluted synovial fluid can be obtained from the majority of small joints. This has important clinical and research implications.

Download full-text PDF

Source
http://dx.doi.org/10.1093/rheumatology/keg269DOI Listing

Publication Analysis

Top Keywords

needle placement
24
synovial fluid
20
small joints
12
mcp joints
12
ultrasound guidance
8
joints
8
accuracy palpation-guided
8
high frequency
8
ultrasound-guided needle
8
placement small
8

Similar Publications

CT-guided C1-C2 facet joint injections are a valuable tool for managing cervicogenic headaches caused by degenerative and inflammatory conditions of the atlantoaxial joint. This video article presents the procedural technique for a CT-guided C1-C2 facet joint injection in a patient with left-sided cervicogenic headache. Despite concerns regarding potential complications such as vascular injury to the vertebral artery and nerve injury to the C2 dorsal root ganglion, careful anatomic planning and imaging guidance allows safe and effective treatment.

View Article and Find Full Text PDF

This study aimed to evaluate the impact of different manipulation methods and storage environments on the microstructural, chemical, and mechanical properties of calcium-enriched mixture (CEM) cement. Four sample groups were examined, including nondried (ND-I) and dried (D-I) groups placed directly in an incubator, dried samples stored in phosphate-buffered saline (PBS) (D-P), and dried samples stored in distilled water (D-W). Various analyses, including Vickers microhardness, compressive strength, Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), and scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS) were conducted after incubating the samples for 7 days.

View Article and Find Full Text PDF

Prcis: In the real-world, retrospective, EXPAND study of consecutive adults with glaucoma, ab-externo gel stent implantation effectively lowered intraocular pressure (34%) and the medication burden (61%), with transient/self-resolving hypotony as the most frequent adverse event (28%).

Purpose: To assess effectiveness and safety of ab-externo gel stent (GS) implantation in glaucoma.

Methods: Multicenter, real-world, retrospective study.

View Article and Find Full Text PDF

Purpose: Spinal cord stimulation (SCS) is pivotal in treating chronic intractable pain. To elucidate the mechanism of action among conventional and current novel types of SCSs, a stable and reliable electrophysiology model in the consensus animals to mimic human SCS treatment is essential. We have recently developed a new in vivo implantable pulsed-ultrahigh-frequency (pUHF) SCS platform for conducting behavioral and electrophysiological studies in rats.

View Article and Find Full Text PDF

Background: The aim of this study was to compare microwave ablation (MWA) with and without prior placement of an intra-arterial catheter for the purpose of application of contrast medium (CM).

Methods: 148 patients (45 female, 65.1 ± 14.

View Article and Find Full Text PDF