Purpose: To evaluate dentin bond durability using current dentin adhesive resin bonding approaches over a 15-month period of water storage.

Materials And Methods: Forty-four extracted human molars were polished with 600-grit SiC papers exposing occlusal dentin, and randomly distributed into four adhesive groups: total-etch 3-step (TE3) (Scotchbond Multi-Purpose, 3M ESPE), total-etch 2-step (TE2) (Single Bond, 3M ESPE), self-etch 2-step (SE2) (Clearfil SE Bond, Kuraray), and a self-etch 1-step (SE1) (Prompt L-Pop, 3M ESPE). A resin composite crown was incrementally formed and light cured to approximately 6 mm in height. Microtensile specimens were fabricated and stored in distilled water containing 0.5% chloramine T and tensile tested at 1 mm/min after 1, 6, and 15 months. The debond pathway was recorded as either involving the substrate or joint using scanning electron microscopy. SAS software was used to compute Weibull parameters and distributions, Log-rank and Wilcoxon tests were used for comparison of survival curves over time for each adhesive system and between adhesive systems.

Results: The TE2 was significantly weaker than TE3 and SE2 after 1 and 6 months of storage, but all three systems were equivalent after 15 months of storage. The SE1 system could not be tested due to 58 of 65 specimens failing during specimen preparation. Failure modes were observed to be dependent upon adhesive system, with only the total-etch 2-step system demonstrating an increasing involvement in the adhesive joint over time.

Conclusion: Although differences in bond strength were observed across adhesive systems up to 6 months of storage, no differences were noted at 15 months. This may represent common degradative mechanisms.

Download full-text PDF

Source

Publication Analysis

Top Keywords

total-etch 2-step
12
months storage
12
bond strength
8
total-etch 3-step
8
2-step self-etch
8
self-etch 2-step
8
self-etch 1-step
8
adhesive system
8
adhesive
7
total-etch
5

Similar Publications

The purpose of this study was to determine the most effective method for bonding composite resin to artificially aged amalgam. A spherical amalgam alloy was triturated and condensed by hand into cylindrical plastic molds (6 mm in diameter and 4 mm in height) to create 90 specimens, which were then aged for 2 weeks in closed plastic containers at 23°C. The amalgam surfaces underwent 1 of 3 surface treatments (n = 30 per treatment): (1) air particle abrasion (APA) with 50-μm aluminum oxide particles applied with a force of 45 psi from a 10-mm distance, followed by rinsing with deionized water for 60 seconds; (2) APA following the same protocol with subsequent application of a metal primer (Alloy Primer); or (3) coating with 30-μm silica (CoJet) at a force of 45 psi from a 10-mm distance until the surface turned black.

View Article and Find Full Text PDF

Objective: To compare 2 different resin composites and 2 adhesive systems used in a new restorative protocol (partial restoration) to treat non-carious cervical lesions associated with gingival recession type 1 (RT1).

Material And Methods: Eighty combined defects (CDs) were treated with a partial restoration and periodontal plastic surgery for root coverage. The CDs were randomly assigned to one of the following groups: NP + TE (n = 20), nanofilled composite and 2-step total-etch adhesive system; NP + UA (n = 20), nanofilled composite and universal adhesive system; MH + TE (n = 20), microhybrid composite and 2-step total-etch adhesive; MH + UA (n = 20), microhybrid composite and universal adhesive.

View Article and Find Full Text PDF

Triacrylamide-Based Adhesives Stabilize Bonds in Physiologic Conditions.

J Dent Res

June 2022

Division of Biomaterials and Biomechanics, Department of Restorative Dentistry, School of Dentistry, Oregon Health & Science University, Portland, OR, USA.

In this study, an acrylamide-based adhesive was combined with a thiourethane-based composite to improve bond stability and reduce polymerization stress, respectively, of simulated composite restorations. The stability testing was conducted under physiologic conditions, combining mechanical and bacterial challenges. Urethane dimethacrylate was combined with a newly synthesized triacrylamide (TMAAEA) or HEMA (2-hydroxyethyl-methacrylate; control) to produce a 2-step total-etch adhesive system.

View Article and Find Full Text PDF

Objectives: Thio-urethane oligomeric additives have been shown to improve the mechanical properties of dental composites and resin cements. To try to harness those same properties in dental adhesives, in this study, these oligomers (TU) were added to the matrix and/or as filler functionalization of experimental adhesives, and the effects on conversion and mechanical properties were analyzed.

Methods: BisGMA and HEMA (60/40 wt%) were used as the monomer matrix, made polymerizable by the addition of 0.

View Article and Find Full Text PDF

Statement Of Problem: Bond strength (BS) values from in vitro studies are useful when dentists are selecting an adhesive system, but there is no ideal measuring method.

Purpose: The purpose of this in vitro study was to investigate the influence of the evaluation method in the BS between dentin and composite resin.

Material And Methods: Molars with exposed superficial dentin (N=240) were divided into 3 groups according to the test: microtensile (μTBS), microshear (μSBS), and micropush-out (μPBS).

View Article and Find Full Text PDF