The Sanita-kun Aerobic Count consists of a transparent cover film, an adhesive sheet, a layer of nonwoven fabric, and a water-soluble compound film, including a culture medium formula for detection of aerobic microorganisms. The Sanita-kun sheet was validated for 14 food categories in an internal study and an independent study was conducted on ground beef and hot dogs. Both studies showed no significant difference in performance between 5 or 8 replicates of the Sanita-kun sheets and AOAC Method 966.23, excluding some lots of foods. The correlation coefficient to plate count agar in the internal accuracy study was 0.99. The average relative standard deviation for repeatability of total foods was 0.26 and 0.19, respectively, excluding < 10 average counts. The ruggedness study, which examined the influence of incubation temperature and period, recommended incubation of the Sanita-kun sheet at 32.5 +/- 2.5 degrees C for 46 +/- 2 h. Comparison of 3 lots of Sanita-kun sheets showed no decrease of performance in the older lot. The shelf-life of the sheet is at least 14 months. The Sanita-kun Aerobic Counts has been granted AOAC Performance Tested Method status.
Download full-text PDF |
Source |
---|
J Food Prot
October 2015
Department of Food Bioscience and Biotechnology, College of Bioresource Science, Nihon University, 1866 Kameino, Fujisawa, Kanagawa 252-0880, Japan.
A novel dry sheet culture method (Sanita-kun ACplus; SkACp) for rapid enumeration of total viable count has been developed. This rehydrated plate system comprises an adhesive sheet, nonwoven fabric coated with nutrients, and two types of water absorption polymers. In addition, SkACp facilitates methods for both rapid count (rapid mode: 24-h incubation) and accurate enumeration (standard mode: 48-h incubation) because it not only contains conventional 2,3,5-triphenyltetrazolium chloride but also contains two kinds of new tetrazolium salts for rapid and accurate enumeration of total aerobic count.
View Article and Find Full Text PDFPrev Nutr Food Sci
December 2013
Department of Food Science and Technology, Yeungnam University, Gyeongbuk 712-749, Korea.
This study was performed to compare the performance of Sanita-Kun dry medium culture plate with those of traditional culture medium and Petrifilm dry medium culture plate for the enumeration of the mesophilic aerobic bacteria in milk, ice cream, ham, and codfish fillet. Mesophilic aerobic bacteria were comparatively evaluated in milk, ice cream, ham, and codfish fillet using Sanita-Kun aerobic count (SAC), Petrifilm aerobic count (PAC), and traditional plate count agar (PCA) media. According to the results, all methods showed high correlations of 0.
View Article and Find Full Text PDFJ AOAC Int
July 2003
Chisso Corp., 13-1 Kachidoki 3 Chome, Chuo-ku, Tokyo 104-8555, Japan.
The Sanita-kun Aerobic Count consists of a transparent cover film, an adhesive sheet, a layer of nonwoven fabric, and a water-soluble compound film, including a culture medium formula for detection of aerobic microorganisms. The Sanita-kun sheet was validated for 14 food categories in an internal study and an independent study was conducted on ground beef and hot dogs. Both studies showed no significant difference in performance between 5 or 8 replicates of the Sanita-kun sheets and AOAC Method 966.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!