Accurate mass measurement by electrospray ionization quadrupole mass spectrometry: detection of variants differing by <6 Da from normal in human hemoglobin heterozygotes.

Anal Chem

Division of Clinical Chemistry, Department of Medical Laboratory Sciences and Technology, Huddinge University Hospital C1 74, Karolinska Institutet, SE-141 86 Stockholm, Sweden.

Published: May 2003

Mass spectrometry has a basic limitation when human hemoglobin variants are analyzed, because it cannot resolve two globin chains that differ in mass by <6 Da. Several common beta-chain variants differ by 1 Da from normal and, hence, when present in heterozygotes, are not resolved from the normal beta-chain. Normal and variant chains appear together in the spectrum as a single entity, whose mass is the abundance weighted mean of the two chains. Here we show that such heterozygotes can be detected in 500-fold diluted blood by accurately measuring the mass of the beta-chain using an electrospray ionization quadrupole instrument and the alpha-chain for internal mass calibration. A statistical analysis of the normal beta-chain mass (n = 86) showed that the standard deviation (SD) of the mean was <+/-0.05 Da (<+/-3.2 ppm). Hence, at the 95% confidence level (+/-2 SD), an abnormal alpha- or beta-chain differing by 1 Da from normal should be detectable in a heterozygote provided its abundance is >10% of total alpha- or beta-chains, respectively. Variants whose masses lay between 1 and 4 Da from normal were detected in 19 heterozygotes. Moreover, the proportion of each variant estimated from the mass change correlated with the proportion determined by cation-exchange HPLC. Variants were assigned to the alpha- or beta-chain by combining the sign of the mass change with the polarity change inferred from electrophoretic data. This procedure could be used for screening clinically significant hemoglobin variants.

Download full-text PDF

Source
http://dx.doi.org/10.1021/ac026228hDOI Listing

Publication Analysis

Top Keywords

accurate mass
4
mass measurement
4
measurement electrospray
4
electrospray ionization
4
ionization quadrupole
4
quadrupole mass
4
mass spectrometry
4
spectrometry detection
4
detection variants
4
variants differing
4

Similar Publications

Background: Paragangliomas are rare neoplasms arising from extra-adrenal chromaffin cells, with mediastinal paragangliomas representing an exceptionally rare subset. This report details the surgical management of a complex mediastinal paraganglioma case, presenting with refractory hypertension and invasion of critical surrounding structures. A comprehensive review of the current literature is included to underscore existing cases, enhance clinical awareness, and share our insights and experience in the diagnosis and treatment of this challenging condition.

View Article and Find Full Text PDF

Protein concentration and analyzing charge variants in a co-formulation comprising three monoclonal antibodies: A cation-exchange chromatography approach.

Int J Pharm

January 2025

BioDev Drug Product Development Department, WuXi Biologics, 190 Hedan Road, Shanghai 200131, China. Electronic address:

In the realm of therapeutic antibodies, co-formulations comprising two or more monoclonal antibodies (mAbs) have emerged as a promising strategy, offering enhanced treatment efficacy, improved efficiency, and prolonged intellectual property protection. These advantages have sparked significant interest among both patients and pharmaceutical companies. However, the quantification and analysis of individual mAbs within such co-formulations pose a substantial challenge due to their similar physicochemical properties.

View Article and Find Full Text PDF

Effective prediction of organosilicon molecular structures and risks in aquatic environment with machine learning.

Sci Total Environ

January 2025

State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; School of Environment, Hangzhou Institute for Advanced Study, UCAS, Hangzhou 330106, China.

Until now, mass spectrometry databases lack molecular information of most organosilicon oligomers, and risk models needing accurate molecular descriptors are unavailable for these emerging contaminants with thousands of monomers. To address this issue, based on molecular/fragment ions and relative abundance from GC-Orbitrap-MS, this study developed appropriate classification (accuracies = 0.750-0.

View Article and Find Full Text PDF

Objective: Alzheimer's disease (AD) and dementia with Lewy bodies (DLB) are common neurodegenerative diseases with distinct but overlapping pathogenic mechanisms. The clinical similarities between these diseases often result in high misdiagnosis rates, leading to serious consequences. Peripheral blood mononuclear cells (PBMCs) are easy to collect and can accurately reflect the immune characteristics of both DLB and AD.

View Article and Find Full Text PDF

Background: Adenoid cystic carcinoma of the breast is a rare subtype, constituting less than 3.5% of primary breast carcinomas. Despite being categorized as a type of triple-negative breast cancer, it generally has a favorable prognosis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!