We have developed an intravascular thermography basket catheter to measure the temperature of the vessel wall to locate foci of inflammation. Our 3 Fr thermography basket catheter is a thermocouple-based catheter made of a nitinol expandable and externally controllable basket system loaded with nine small and flexible built-in thermosensors. It is equipped with real-time data acquisition software with a thermal resolution of 0.0001 degrees C and a sampling rate of 20 readings per second. In 10 inbred cholesterol-fed dogs with femoral (but not carotid) atherosclerosis, we found foci of warmth on the surface of atherosclerotic but not disease-free regions (P < 0.05). Marked temperature heterogeneity was also observed in the aortas of atherosclerotic Watanabe rabbits but not in normal rabbits. The catheters showed satisfactory accuracy, reproducibility, and safety. If confirmed in further studies, it has the potential to be utilized in detection of vulnerable plaques.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/ccd.10486 | DOI Listing |
J Clin Med
February 2023
Department of Urology, Wakayama Medical University, 811-1 Kimiidera, Wakayama City 641-0012, Japan.
J Endourol
February 2023
Department of Urology, Wakayama Medical University Hospital, Wakayama, Japan.
This study aims to evaluate changes in irrigation fluid temperatures during laser activation by using thermography, with comparison between Moses mode (MM) and virtual basket mode (VBM). Experiments were performed using an unroofed pyelocaliceal model. The laser was fired for 60 seconds at 0.
View Article and Find Full Text PDFCatheter Cardiovasc Interv
May 2003
Center for Vulnerable Plaque Research, University of Texas-Houston Health Science Center, Houston, Texas, USA.
We have developed an intravascular thermography basket catheter to measure the temperature of the vessel wall to locate foci of inflammation. Our 3 Fr thermography basket catheter is a thermocouple-based catheter made of a nitinol expandable and externally controllable basket system loaded with nine small and flexible built-in thermosensors. It is equipped with real-time data acquisition software with a thermal resolution of 0.
View Article and Find Full Text PDFAm J Cardiol
November 2002
Division of Cardiology/Internal Medicine, University of Texas-Houston Health Science Center, USA.
In 1996, we showed that inflamed atherosclerotic plaques give off more heat and that vulnerable plaques may be detected by measuring their temperature. Plaque temperature is correlated directly with inflammatory cell density and inversely with the distance of the cell clusters from the luminal surface. It is inversely related to the density of the smooth muscle cells.