The cochlear implantation program in Poznań started in January 1994. Within 8 years, 151 patients were implanted (149 cochlear and 2 auditory brain-stem implants). The implanted group comprised 111 children and 40 adults. We have extended the lower age limit for cochlear implant candidates, and the youngest implanted patient was 18-months-old at the time of surgery. We have also implanted six multi-handicapped subjects. All patients were implanted with different nucleus devices (22, 24 M, 24 K, 24 Contour, 24 Double Array and 24 ABI). Insertion of the Nucleus 24 Contour electrode carrier requires a little larger cochleostomy in comparison with conventional straight array. After insertion, the intraoperative measurements are taken (impedance telemetry, electrically evoked stapedius reflex and NRT). The day after surgery, each patient undergoes an X-ray examination (the cochleogram or cochlear view). The calculated length of the electrode array insertion was 12.75-24.0 mm (mean: 22.05 mm) and the degree of electrode rotation was 180-540 degrees (mean: 292.82 degrees). After speech processor switch-on, we performed NRT measurements. Our results indicated that the NRT threshold was in 51.4% of the dynamic range within the group of examined patients. The adults' progress of rehabilitation was checked during individual sessions. The rehabilitation of children included two rehabilitation schedules: continuous ones and weekly rehabilitation camps. The progress of the recovery process of implanted children enabled them to change their school profile from hearing impaired to mainstream. Voice rehabilitation is often monitored by acoustic analysis using the Multi Dimensional Voice Program (MDVP).
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00405-003-0586-y | DOI Listing |
J Comp Eff Res
January 2025
Boston Scientific Corporation; 100 Boston Scientific Way, Marlborough, MA, USA.
This study assessed the economic impact of reducing one postoperative visit following inflatable penile prosthesis (IPP) implantation. Scenario analyses were used to model the effects of eliminating one 30-min IPP postoperative visit from the expected 2.5 visits accounted for by the American Medical Association resource-based relative value scale data.
View Article and Find Full Text PDFCurr Med Imaging
January 2025
Consultant in Emergency Medicine, WIC Clinic, Primary Health Care Corporation, Doha, Qatar.
Introduction: Pneumocephalus and pneumorrhachis are rare postoperative complications, commonly occurring within a few days to months after spinal surgery. They are very rarely reported after thoracic surgeries. This case highlights a unique presentation in the emergency department involving headache and vomiting caused by late complications following thoracic surgery with a titanium rib implant.
View Article and Find Full Text PDFAdv Healthc Mater
January 2025
Beijing Key Laboratory of Preclinical Research and Evaluation for Cardiovascular Implant Materials, Animal Experimental Centre, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100037, China.
Myocarditis, a leading cause of sudden cardiac death and heart transplantation, poses significant treatment challenges. The study of clinical samples from myocarditis patients reveals a correlation between the pathogenesis of myocarditis and cardiomyocyte mitochondrial DNA (mtDNA). During inflammation, the concentration of mtDNA in cardiomyocytes increases.
View Article and Find Full Text PDFJ Educ Health Promot
November 2024
Department of Cardiology, Jawaharlal Institute of Postgraduate Medical Education and Research (JIPMER), Puducherry, India.
Background: Cardiac rehabilitation programs are planned to reduce the physiological and psychological stress of Cardiovascular Disease, decrease the risk of mortality secondary to CVD, improve cardiovascular function, and help patients to achieve their highest quality of life. However, data on the safety and efficacy of exercise training (ET) in patients with implantable cardioverter defibrillators (ICDs) is sparse. Exercise interventions in those with an ICD have not been extensively studied.
View Article and Find Full Text PDFEur Heart J Case Rep
January 2025
1st Department of Arrhythmia, National Institute of Cardiology, 42 Alpejska Street, 04-628 Warsaw, Poland.
Background: Transvenous lead extraction (TLE) has become an essential component of lead management strategies, but it carries the risk of severe complications, including damage to the tricuspid valve. Currently, there are no established predictors that can help prevent these complications.
Case Summary: An 84-year-old male with a dual-chamber pacemaker was admitted to the hospital due to a pocket fistula resulting from a local infection.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!