A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Flow control valves for analytical microfluidic chips without mechanical parts based on thermally responsive monolithic polymers. | LitMetric

Monolithic plugs of poly(N-isopropylacrylamide) cross-linked with 5% methylenebisacrylamide have been prepared by photoinitiated polymerization within the channel of a microfluidic device. The volume change associated with the polymer phase transition at its lower critical solution temperature of 32 degrees C allows both the rapid swelling and the deswelling of the monoliths enabling the polymer to close or open the channel as it functions as a nonmechanical valve. Thermoelectric elements capable of changing the temperature of the system between 17 and 57 degrees C were used to actuate the valve. Flow through the device was monitored by fluorescence measurements via the laser-triggered photobleaching of a dye contained in the liquid phase. Photobleaching occurs quickly once the flow is stopped, and the time required to open and close the valve was 3.5 and 5.0 s, respectively. No changes in function were observed even after 120 open-close cycles. Although the 2-mm-long valve was prepared from a polymerization mixture consisting of only a 5% aqueous solution of monomers, it resists pressures of up to 1.38 MPa (200 psi) without observable structural damage.

Download full-text PDF

Source
http://dx.doi.org/10.1021/ac026455jDOI Listing

Publication Analysis

Top Keywords

flow control
4
control valves
4
valves analytical
4
analytical microfluidic
4
microfluidic chips
4
chips mechanical
4
mechanical parts
4
parts based
4
based thermally
4
thermally responsive
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!