The ZstatFlu-II test is a highly sensitive, specific, rapid, point-of-care chemiluminescent diagnostic test for influenza infection. Influenza viral neuraminidase-specific substrate, spiroadamantyl-1,2-dioxetane-4,7-dimethoxy-N-acetyl-neuraminic acid, is at the core of the ZstatFlu-II Test. The enzymatic reaction was carried out at 25 degrees C and neutral pH, representing the optimum assay conditions for influenza types A and B viral neuraminidases. The results were outputted on a Polaroid trade mark High Speed Detector Film. Positive results appeared as a '+'-shaped white film image; negative results produced no image. The 'glow' kinetics, facilitated by a unique combination of light enhancers, also 'tuned' the wavelength of emission to match the spectral properties of the film. The substrate hydrolysed non-enzymatically at acid pH or at temperatures above 25 degrees C. In order to minimize false positives, the ZstatFlu-II Test was formatted with 0.3-0.4 K(m) substrate and freezing the test kit until use. The pH optimization of the ZstatFlu-II test is discussed with reference to model compounds of sialyl-glycosides. A nucleophilic attack or an electrostatic stabilization of a developing carbonium ion under the influence of the adjacent carboxyl group was probably responsible for non-enzymatic hydrolysis of the substrate. Intramolecular general acid catalysis is proposed as a mechanism for the lability of the O-glycosidic linkage of the substrate.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/bio.714 | DOI Listing |
Anal Bioanal Chem
September 2014
Chemiluminescent reactions have found application in a number of commercial point-of-care and on-site testing devices. Notable examples include allergy tests (e.g.
View Article and Find Full Text PDFLuminescence
February 2004
QTL Biosystems, Santa Fe, NM 87507, USA.
The ZstatFlu-II test is a highly sensitive, specific, rapid, point-of-care chemiluminescent diagnostic test for influenza infection. Influenza viral neuraminidase-specific substrate, spiroadamantyl-1,2-dioxetane-4,7-dimethoxy-N-acetyl-neuraminic acid, is at the core of the ZstatFlu-II Test. The enzymatic reaction was carried out at 25 degrees C and neutral pH, representing the optimum assay conditions for influenza types A and B viral neuraminidases.
View Article and Find Full Text PDFLuminescence
December 2003
QTL Biosystems, 2778 Agua Fria, Bldg. C Suite BC, Santa Fe, NM 87507, USA.
We describe the engineering and product development of the chemiluminescent ZstatFlu-II Test kit for influenza diagnostics. The reaction vessel is a chemical implementation device with a polystyrene bottom chamber and a polypropylene top chamber that screw together. The patient's specimen is dispersed in a proprietary diluent and mixed inside the bottom chamber with the influenza viral neuraminidase-specific substrate, 1,2-dioxetane-4,7-dimethoxy-Neu5Ac.
View Article and Find Full Text PDFJ Clin Microbiol
July 2002
University of Missouri-Kansas City School of Medicine, Kansas City, Missouri, USA.
Exploiting the high sensitivity of the chemiluminescence phenomenon, an accurate and sensitive point-of-care test, called the ZstatFlu-II test (ZymeTx, Inc., Oklahoma City, Okla.), was developed to detect influenza virus infections.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!