Our objective was to assess the clinical value of an early arterial scan for assessing the hepatic and mesenteric vasculature in patients with suspected primary or metastatic hypervascular liver disease undergoing multislice computed tomography. In 42 patients a very early arteriographic scan was performed before standard arterial and portal venous scans. Technical parameters of the very early acquisition were: 2.5-mm image thickness; table speed 15 mm/s; pitch 6; 120 kVp; 300 mA; 8.9-s scan time; cranio-caudal acquisition direction; 1.25-mm image interval reconstruction;16-s delay after injection of 110 ml of iodinated contrast agent at 5 ml/s; scan volume focused to image hepatic, splenic, and superior mesenteric arteries (SMA). Standard arterial and portal venous phases were performed with 5-mm image thickness, 15-mm/s table speed, pitch 6, 8- to 10-s scan time, 30- and 70-s delay. The three phases were performed during three different breath-holds. Axial, multiplanar reformatted, maximum intensity projection, and volume-rendering images were evaluated. Image quality was scored, and vascular abnormalities were recorded. Digital subtraction angiography (DSA) was performed in 17 patients. In 36 of 42 patients good-quality CT angiograms were obtained. In 9 patients 12 vascular abnormalities were found, all confirmed at DSA: 3 right hepatic arteries originating from the SMA, 2 left hepatic arteries from the gastric artery, 2 stenoses of the SMA, 1 independent origin of the hepatic and splenic arteries, 2 arteriovenous fistulas, and 2 aneurysms of the common hepatic artery and the SMA. This technique could add important information about vascular splanchnic anatomy which would be particularly useful for surgeons and interventional radiologists.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00330-002-1566-0 | DOI Listing |
Ann Vasc Surg
September 2024
University Professor, Dijon University Hospital, Dijon, France.
Background: The primary treatment for lower-extremity peripheral arterial occlusive disease (PAOD) is angioplasty stenting. Its main complication is in-stent restenosis. Poor selection of stent dimensions has been identified as a factor contributing to early in-stent restenosis.
View Article and Find Full Text PDFFront Cardiovasc Med
March 2024
Division of Cardiovascular Medicine, Department of Clinical Sciences, Danderyd Hospital, Karolinska Institutet, Stockholm, Sweden.
Introduction: Aortic stiffness plays a critical role in the evolution of cardiovascular diseases, but the assessment requires specialized equipment. Photoplethysmography (PPG) and single-lead electrocardiogram (ECG) are readily available in healthcare and wearable devices. We studied whether a brief PPG registration, alone or in combination with single-lead ECG, could be used to reliably estimate aortic stiffness.
View Article and Find Full Text PDFSci Rep
May 2023
Department of Internal Medicine and Diabetology, Poznan University of Medical Sciences, ul. Mickiewicza 2, 60-834, Poznań, Poland.
Arterial stiffness (AS) and non-dipping pattern are early predictors of cardiovascular diseases but are not used in clinical practice. We aimed to assess if AS and the non-dipping pattern are more prevalent in the erectile dysfunction (ED) group than in the non-ED group among subjects with type 1 diabetes (T1DM). The study group consisted of adults with T1DM.
View Article and Find Full Text PDFAnn Vasc Surg
March 2023
Bypass Solutions, Marseille, France; Université Aix-Marseille 2 et service de chirurgie vasculaire, Centre Hospitalo-Universitaire Nord Marseille, France. Electronic address:
Background: To offer an alternative to conventional techniques of lateral prosthetic anastomosis on arteries which require a long training, and impose an extensive open surgery, we are proposing the clampless 2 device (C2D) implanted by a simple arterial puncture and allows a lateral implantation of a polytetrafluoroethylene (PTFE) vascular graft in an artery, without arterial clamping or suture.
Methods: C2D is a "T" shaped 25-mm long and 8-mm diameter Nitinol stent with a 6-mm PTFE graft prosthesis mounted laterally on the stent, and implanted in an artery, via a 21-French sheath, and a compliant balloon inflation. In vitro testing of the C2D was first performed on a bench including a segment of a 7-mm internal diameter pig abdominal aorta.
Front Endocrinol (Lausanne)
February 2022
Faculty of Sport and Health Sciences, University of Jyväskylä, Jyväskylä, Finland.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!