In peripheral and coronary bypass surgery, the patency of prosthetic grafts is inferior to autologous vein, mainly due to intimal hyperplasia caused in part by compliance mismatch between rigid graft and elastic host artery. We have developed a compliant poly(carbonate-urea)urethane vascular graft "MyoLink" which was biostable in vitro degradation studies. To further investigate the biostability of this material, we report a long-term in vivo study on 8 beagle dogs (15+/-3 kg) implanted with this graft (ID 5mm) in the aorta-iliac position; three grafts were harvested at 18 months to assess short-term biodegradation, with one animal having died from an unrelated infection. The 4 remaining grafts were harvested at 36 months for analysis by: (1) histology, (2) compliance measurements and (3) environmental scanning electron microscopy (ESEM); gel permeation chromatography (GPC); attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR) and radial tensile strength analysis. There was no infection or inflammation of the grafts or surrounding tissues. Histological analysis showed a well-developed neointima but only at the distal anastomosis. There were no significant differences in compliance pre- and post-implantation and no evidence of material curvature, radial expansion or chemical breakdown, ESEM and GPC showed no signs of degradation. Peak height analysis with ATR-FTIR of the 1740 cm(-1) (C=O of carbonate) and 1253 cm(-1) bands (C-O-C of CO-O-C) showed a loss of carbonate carbonyl but was not statistically significant. Radial tensile strength remained within batch release specifications.This polyurethane graft retains its compliance post-implantation, whilst exhibiting only a minor hydrolysis of the amorphous segment, confirming its biostability in vivo up to 3 years.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0142-9612(02)00608-7 | DOI Listing |
Int J Mol Sci
December 2024
Department of Orthopedic Surgery, E-Da Hospital, I-Shou University, Kaohsiung City 824, Taiwan.
Olfactory ensheathing cell (OEC) transplantation demonstrates promising therapeutic results in neurological disorders, such as spinal cord injury. The emerging cell-free secretome therapy compensates for the limitations of cell transplantation, such as low cell survival rates. However, the therapeutic benefits of the human OEC secretome remain unclear.
View Article and Find Full Text PDFOrbit
January 2025
Department of Oculoplastic, Orbital and Lacrimal Surgery, Aichi Medical University Hospital, Nagakute, Japan.
Purpose: To describe a technique using retroauricular scalp graft for eyebrow reconstruction, along with problems encountered and countermeasures in treatment.
Methods: We present a patient with eyebrow loss following resection of a malignant schwannoma. We initially covered the defect from the upper eyelid to the eyebrow area with artificial dermis for hemostasis and to increase the granulation of the graft bed.
J Craniofac Surg
January 2025
Division of Plastic and Reconstructive Surgery, The Warren Alpert Medical School of Brown University.
Background: Cranial defects from trauma, surgery, or congenital conditions require precise reconstruction to restore cranial vault integrity. Autogenous calvarial grafts are preferred for their histocompatibility and biomechanical properties, but their success depends on a well-developed diploic space. Although prior studies have described overall skull thickness development, less is known about how diploic thickness changes through adulthood.
View Article and Find Full Text PDFOral Maxillofac Surg
January 2025
Department of Maxillofacial Surgery, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, 1-5-45, Yushima, Bunkyo-ku, Tokyo, 113-8510, Japan.
Purpose: Current scapular free flap (SFF) harvest in mandibular reconstruction often requires repositioning, hindering simultaneous harvest and resection and potentially increasing ischemic time. This study evaluated the efficacy of the pull-through technique (PTT) for SFF harvest, aiming to reduce ischemic time during mandibular segmental resection.
Methods: A retrospective analysis was conducted on 24 patients who underwent mandibular reconstruction using SFF at two maxillofacial surgery departments between January 2015 and May 2022.
Arthrosc Tech
December 2024
Department of Orthopaedic Surgery, University of Colorado School of Medicine, Aurora, Colorado, U.S.A.
Anterior cruciate ligament reconstruction with quadriceps tendon autograft is a reliable graft option that has recently increased in use. Varying harvesting and graft preparation techniques available and improved technology and implant design continue to make quadricep tendon preparation more efficient and reproducible. In this Technical Note, we describe our preferred technique for all-soft tissue quadriceps tendon autograft preparation after harvest for anterior cruciate ligament reconstruction.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!