The authors hypothesized that the persistence of abnormal atrial conduction detected by serial P wave signal-averaged electrocardiograms (P-SAECGs) can identify patients who are at high risk of recurrent atrial fibrillation (R-AF) following electrical cardioversion (ECV). P-SAECGs were recorded in 60 consecutive patients after ECV (53 men, age 66 +/- 10 years) and repeated in those who had remained in sinus rhythm (SR) 1 week, and 1, 3, and 6 months later. Filtered P wave duration (PD), root mean square (RMS) voltage of the terminal 40, 30, 20 ms (RMS-40, RMS-30, RMS-20) of the filtered P wave, RMS voltage of the entire filtered P wave (RMS-p), and the integral of the voltages in the entire P wave (integral-p) were analyzed. Thirty-one (52%) patients returned to AF within 1 week, an additional 11 (18%) by 1 month, and a further 2 (3.3%) at each subsequent assessment (3 and 6 months). The patients with R-AF had longer PD (157 +/- 24 vs 143 +/- 17 ms, P < 0.0001) and lower RMS-40, RMS-30, RMS-20 (5.3 +/- 2.0 vs 6.1 +/- 3.4 microV, P = 0.007; 4.3 +/- 1.5 vs 5.7 +/- 3.2 microV, P < 0.0001; 3.6 +/- 1.4 vs 5.2 +/- 3.0 microV, P < 0.0001, respectively) than those who remained in SR. These measurements did not change significantly in either group. RMS-p increased in SR patients (P = 0.009) but decreased in those who subsequently reverted to AF (P = 0.032) with a significant difference between the slopes of the RMS-p change (P = 0.006). Integral-p decreased from the time of ECV in the R-AF group only (P = 0.0028) and created a significant difference between the two slopes (P = 0.0004). The evolution of P-SAECG parameters after ECV differs in patients whose AF recurs versus patients who remain in SR.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1046/j.1460-9592.2003.00037.x | DOI Listing |
Nanophotonics
January 2025
MOE Key Laboratory of Advanced Micro-Structured Materials, School of Physics Science and Engineering Tongji University, Shanghai 200092, China.
The formed optical cavity mode intensively relies on the size and geometry of optical cavity. When the defect or impurity exists inside the cavity, the formed cavity mode will be destroyed. Here, we propose a metacavity consisting of arrays of linear-crossing metamaterials (LCMMs) with abnormal dispersion, where each LCMM offers both the directional propagation channel for all incident angles and the negative refraction across its neighboring LCMMs.
View Article and Find Full Text PDFSci Rep
January 2025
College of Computer Science and Engineering, Northwest Normal University, Lanzhou, 730070, Gansu, China.
Heart disease is a significant global health issue. Traditional methods for heart rate monitoring typically require close physical contact, which limits the continuity and convenience of monitoring. To achieve real-time, non-contact heartbeat monitoring, researchers have introduced millimeter-wave radar technology.
View Article and Find Full Text PDFMed Biol Eng Comput
January 2025
Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Science, Suzhou, 215613, China.
Ultrasound blood flow imaging plays a crucial role in the diagnosis of cardiovascular and cerebrovascular diseases. Conventional ultrafast ultrasound plane-wave imaging techniques have limited capabilities in microvascular imaging. To enhance the quality of blood flow imaging, this study proposes a microbubble-based H-Scan ultrasound imaging technique.
View Article and Find Full Text PDFUltrasound Med Biol
January 2025
Department of Electrical and Electronic Engineering, The University of Hong Kong, Hong Kong; Biomedical Engineering Programme, The University of Hong Kong, Hong Kong. Electronic address:
Objective: Near-field (NF) clutter filters are critical for unveiling true myocardial structure and dynamics. Randomized singular value decomposition (rSVD) stands out for its proven computational efficiency and robustness. This study investigates the effect of rSVD-based NF clutter filtering on myocardial motion estimation.
View Article and Find Full Text PDFIn this Letter, we propose and experimentally validate a high-fidelity and adaptive forward-phase-based vibration sensing using a Wiener filter (WF). In commercial coherent digital subcarrier multiplexing (DSCM) systems under external cavity lasers (ECLs), frequency-domain pilot tones (FPTs) in subcarrier intervals are employed for dynamic frequency offset estimation (FOE), carrier phase estimation (CPE), and polarization demultiplexing. The phase estimated by the CPE module is processed with the WF to achieve high-fidelity extraction of the vibration-induced phase.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!