Detection of electronically excited species (EES) in body fluids may constitute an important diagnostic tool in various pathologies. Examples of such products are triplet excited carbonyls (TEC), which can be a source for photon emission in the 400-550 nm range. The aim of the present study was to determine the actual contribution of lipid and protein components (protein carbonyls) to photon emission generated by thermochemiluminescence (TCL) during the heating of biological fluids. In this study, a new TCL Photometer device, designed by Lumitest Ltd, Israel, was used. Samples were heated to a constant temperature of 80 +/- 0.5 degrees C for 280 s and photon emission was measured at several time points. In order to compare the results of TCL measurements to conventional methods of detecting lipid and protein oxidation, each examined sample was also heated in a waterbath at 80 degrees C for 10-280 s. Lipid and protein oxidation were subsequently measured using conventional methods. The TCL of four polyunsaturated fatty acids (PUFA) with three to six double bonds was measured. The elevation of the PUFA TCL amplitude correlated with the increase in the number of double bonds of PUFA. A correlation between the increase in TCL intensity and protein carbonyl generation in bovine serum albumin (BSA) was also observed. In the venous blood serum, our study showed that an increase of TCL intensity during heating reflected the cleavage of TEC of lipid origin. Our study suggests that biological molecules such as proteins, lipids and other molecules, which may become unstable during heating, are capable of generating EES. We demonstrated that a TCL curve can be used as a kinetic model for measuring oxidative processes, which reflects modifications of different molecules involved in the oxidative stress phenomena.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/bio.699 | DOI Listing |
Eur J Nucl Med Mol Imaging
December 2024
Department of Nuclear Medicine, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse 18, Bern, 3010, Switzerland.
Purpose: Long axial field-of-view (LAFOV) positron emission tomography/computed tomography (PET/CT) scanners enable high sensitivity and wide anatomical coverage. Therefore, they seem ideal to perform post-selective internal radiation therapy (SIRT) Y scans, which are needed, to confirm that the dose is delivered to the tumors and that healthy organs are spared. However, it is unclear to what extent the use of LAFOV PET is feasible and which dosimetry approaches results in accurate measurements.
View Article and Find Full Text PDFEpilepsia
December 2024
Department of Neurosurgery, Nagoya University School of Medicine, Nagoya, Japan.
Objective: At our institute, most pediatric patients undergo epilepsy surgery following a thorough presurgical evaluation without intracranial electroencephalography (EEG). We conducted an initial validation of our noninvasive presurgical strategy by assessing the seizure and developmental outcomes of 135 children.
Methods: All 135 pediatric patients were <15 years old, had undergone curative surgery, and were followed for at least 2 years postoperatively.
Nanomaterials (Basel)
December 2024
Institute of Photonics and Nanotechnology, Faculty of Physics, Vilnius University, Saulėtekio Ave. 3, 10257 Vilnius, Lithuania.
We elaborate a method for determining the 0D-1D nanostructure size by photoluminescence (PL) emission spectrum dependence on the nanostructure dimensions. As observed, the high number of diamond-like carbon nanocones shows a strongly blue-shifted PL spectrum compared to the bulk material, allowing for the calculation of their top dimensions of 2.0 nm.
View Article and Find Full Text PDFBiosensors (Basel)
December 2024
Department of Chemistry, University of Colombo, Colombo 00300, Sri Lanka.
Bright biocompatible fluorescent imaging dyes with red to near-infrared (NIR) emissions are ideal candidates for fluorescence microscopy applications. Pyrene-benzothiazolium hemicyanine dyes are a new class of lysosome-specific probes reported on recently. In this work, we conduct a detailed implementation study for a pyrene-benzothiazolium derivative, BTP, to explore its potential imaging applications in fluorescence microscopy.
View Article and Find Full Text PDFCurr Oncol
November 2024
Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, 3584 CX Utrecht, The Netherlands.
In same-day radioembolization, 99mTc-MAA SPECT/CT, 90Y radioembolization, and post-treatment 90Y SPECT/CT procedures are conducted on the same-day, resulting in a dual-isotope environment of 90Y and 99mTc during post-treatment imaging. This study aimed to quantify the impact of 99mTc on 90Y bremsstrahlung-SPECT/CT image quality and to establish an optimised imaging protocol for both clinical practice, and with advanced reconstruction techniques. Utilising a NEMA IQ phantom, contrast recovery coefficients (CRCs) were measured to evaluate the 90Y image quality degradation caused by 99mTc.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!