Radiation exposure in multi-slice versus single-slice spiral CT: results of a nationwide survey.

Eur Radiol

Division of Medical Radiation Hygiene and Dosimetry, Institute of Radiation Hygiene, Federal Office for Radiation Protection, Neuherberg, Germany.

Published: August 2003

Multi-slice (MS) technology increases the efficacy of CT procedures and offers new promising applications. The expanding use of MSCT, however, may result in an increase in both frequency of procedures and levels of patient exposure. It was, therefore, the aim of this study to gain an overview of MSCT examinations conducted in Germany in 2001. All MSCT facilities were requested to provide information about 14 standard examinations with respect to scan parameters and frequency. Based on this data, dosimetric quantities were estimated using an experimentally validated formalism. Results are compared with those of a previous survey for single-slice (SS) spiral CT scanners. According to the data provided for 39 dual- and 73 quad-slice systems, the average annual number of patients examined at MSCT is markedly higher than that examined at SSCT scanners (5500 vs 3500). The average effective dose to patients was changed from 7.4 mSv at single-slice to 5.5 mSv and 8.1 mSv at dual- and quad-slice scanners, respectively. There is a considerable potential for dose reduction at quad-slice systems by an optimisation of scan protocols and better education of the personnel. To avoid an increase in the collective effective dose from CT procedures, a clear medical justification is required in each case.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00330-003-1883-yDOI Listing

Publication Analysis

Top Keywords

single-slice spiral
8
dual- quad-slice
8
quad-slice systems
8
effective dose
8
radiation exposure
4
exposure multi-slice
4
multi-slice versus
4
versus single-slice
4
spiral nationwide
4
nationwide survey
4

Similar Publications

Objectives: Recently, epicardial adipose tissue (EAT) assessed by CT was identified as an independent mortality predictor in patients with various cardiac diseases. Our goal was to develop a deep learning pipeline for robust automatic EAT assessment in CT.

Methods: Contrast-enhanced ECG-gated cardiac and thoraco-abdominal spiral CT imaging from 1502 patients undergoing transcatheter aortic valve replacement (TAVR) was included.

View Article and Find Full Text PDF

This work develops and evaluates a self-navigated variable density spiral (VDS)-based manifold regularization scheme to prospectively improve dynamic speech magnetic resonance imaging (MRI) at 3 T. Short readout duration spirals (1.3-ms long) were used to minimize sensitivity to off-resonance.

View Article and Find Full Text PDF

Background: Radiopaque breast markers cause artifacts in dedicated spiral breast-computed tomography (SBCT). This study investigates the extent of artifacts in different marker types and the feasibility of reducing artifacts through a metal artifact reduction (MAR) algorithm.

Methods: The pilot study included 18 women who underwent contrast-enhanced SBCT.

View Article and Find Full Text PDF

The objective of the current study was to develop and evaluate a DEep learning-based rapid Spiral Image REconstruction (DESIRE) technique for high-resolution spiral first-pass myocardial perfusion imaging with whole-heart coverage, to provide fast and accurate image reconstruction for both single-slice (SS) and simultaneous multislice (SMS) acquisitions. Three-dimensional U-Net-based image enhancement architectures were evaluated for high-resolution spiral perfusion imaging at 3 T. The SS and SMS MB = 2 networks were trained on SS perfusion images from 156 slices from 20 subjects.

View Article and Find Full Text PDF

Purpose: To develop and evaluate a high spatial resolution (1.25 × 1.25 mm ) spiral first-pass myocardial perfusion imaging technique with whole-heart coverage at 3T, to better assess transmural differences in perfusion between the endocardium and epicardium, to quantify the myocardial ischemic burden, and to improve the detection of obstructive coronary artery disease.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!