A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Limits of diagnostic accuracy of anti-hepatitis C virus antibodies detection by ELISA and immunoblot assay. | LitMetric

When human sera samples are tested for anti-hepatitis C virus (HCV) antibodies using different ELISA kits as well as immunoblot assay kits discrepant results often occur. As a result the diagnostics of HCV infection in such sera remains unclear. The purpose of this investigation is to define the limits of HCV serodiagnostics. Overall 7 different test kits of domestic and foreign manufacturers were used for the sampled sera testing. Preliminary comparative study, using seroconversion panels PHV905, PHV907, PHV908 was performed and reference kit was chosen (Murex anti-HCV version 4) as the most sensitive kit on the base of this study results. Overall 1640 sera samples have been screened using different anti-HCV ELISA kits and 667 of them gave discrepant results in at least two kits. These sera were then tested using three anti-HCV ELISA kits (first set of 377 samples) or four anti-HCV ELISA kits (second set of 290 samples) at the conditions of reference laboratory. In the first set 17.2% samples remained discrepant and in the second set - 13.4%. "Discrepant" sera were further tested in RIBA 3.0 and INNO-LIA immunoblot confirmatory assays, but approximately 5-7% of them remained undetermined after all the tests. For the samples with signal-to-cutoff ratio higher than 3.0 high rate of result consistency by reference, ELISA routing and INNO-LIA immunoblot assay was observed. On the other hand the results of tests 27 "problematic" sera in RIBA 3.0 and INNO-LIA were consistent only in 55.5% cases. Analysis of the antigen spectrum reactive with antibodies in "problematic" sera, demonstrated predominance of Core, NS3 and NS4 antigens for sera, positive in RIBA 3.0 and Core and NS3 antigens for sera, positive in INNO-LIA. To overcome the problem of undetermined sera, methods based on other principles, as well as alternative criteria of HCV infection diagnostics are discussed.

Download full-text PDF

Source

Publication Analysis

Top Keywords

elisa kits
16
immunoblot assay
12
anti-hcv elisa
12
sera
11
anti-hepatitis virus
8
sera samples
8
hcv infection
8
sera tested
8
second set
8
riba inno-lia
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!