The purpose of this study was to explore the application of the click-evoked and distortion products otoacoustic emissions (CEOAEs and DPOAEs, respectively) in the diagnosis and detection of noise-induced hearing loss (NIHL). The study group consisted of 283 noise-exposed subjects and 176 subjects with a history of noise exposure but with a normal audiogram. Findings were also compared with those in 310 young military recruits with no reported history of noise exposure and normal bilateral audiogram. In general, the features of noise-induced emissions loss (NIEL) closely resembled the behavioural NIHL parameters: both were bilateral and both affected primarily the high frequencies, with a "notch" at around 3 kHz in the DPOAEs. On average, CEOAEs were recorded up to 2 kHz, indicating that up to this frequency range (speech area), cochlear functioning is intact and the hearing threshold s better than 25 dBHL. A clear association between the OAEs and the severity of the NIHL was noted. As the severity of NIHL increased, the emissions range became narrower and the amplitude smaller. OAEs were found to be more sensitive to noise damage than behavioural audiometry. NIEL was found in subjects with normal audiograms but with a history of noise exposure. Owing to their objectivity and sensitivity, OAEs may sometimes provide indispensable information in medico-legal cases, in which the configuration of the audiometric threshold is needed to obtain an accurate diagnosis of NIHL and compensation is proportional to the severity of NIHL. Furthermore, OAE testing between ears with and without NIHL revealed a high sensitivity (79 - 95%) and specificity (84 - 87%). This study shows that OAEs provide objectivity and greater accuracy, complementing the behavioural audiogram in the diagnosis and monitoring of the cochlear status following noise exposure.

Download full-text PDF

Source

Publication Analysis

Top Keywords

noise exposure
16
history noise
12
severity nihl
12
noise-induced hearing
8
hearing loss
8
otoacoustic emissions
8
exposure normal
8
oaes provide
8
nihl
7
noise
5

Similar Publications

Purpose: This study investigated the impact of the field of view (FOV), voxel size, and exposure parameters on the contrast-to-noise ratio (CNR) in cone-beam computed tomography (CBCT).

Materials And Methods: A SedentexCT phantom was scanned using 3D Accuitomo 170 across 3 FOVs (40×40 mm, 60×60 mm, 80×80 mm). Each FOV had 4 settings for kVp and 3 for mA.

View Article and Find Full Text PDF

Sensorineural hearing loss (SNHL) is characterized by a compromised cochlear perception of sound waves. Major risk factors for SNHL include genetic mutations, exposure to noise, ototoxic medications, and the aging process. Previous research has demonstrated that inflammation, oxidative stress, apoptosis, and autophagy, which are detrimental to inner ear cells, contribute to the pathogenesis of SNHL; however, the precise mechanisms remain inadequately understood.

View Article and Find Full Text PDF

Associations of Traumatic Brain Injury and Hearing: Results From the Atherosclerosis Risk in Communities Neurocognitive Study (ARIC-NCS).

J Head Trauma Rehabil

December 2024

Author Affiliations: Department of Neurology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania (Dr Schneider); Department of Biostatistics, Epidemiology, and Informatics, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania (Dr Schneider); Department of Psychiatry and Behavioral Sciences, School of Medicine, Johns Hopkins University, Baltimore, Maryland (Dr Kamath); Department of Epidemiology, Johns Hopkins University Bloomberg School of Public Health, Baltimore, Maryland (Drs Reed, Sharrett, Lin, and Deal); The MIND Center, University of Mississippi Medical Center, Jackson, Mississippi (Dr Mosley); National Institute of Neurological Disorders and Stroke Intramural Research Program, Bethesda, Maryland (Dr Gottesman); Department of Otolaryngology, School of Medicine, Johns Hopkins University, Baltimore, Maryland (Drs Lin and Deal); and Cochlear Center for Hearing and Public Health, Johns Hopkins Bloomberg School of Public Health, Baltimore, Maryland (Drs Lin and Deal).

Objective: To examine associations of traumatic brain injury (TBI) with self-reported and clinical measures of hearing function.

Setting: Four US communities.

Participants: A total of 3176 Atherosclerosis Risk in Communities Study participants who attended the sixth study visit in 2016-2017, when hearing was assessed.

View Article and Find Full Text PDF

Uncovering rates at which susceptible individuals become infected with a pathogen, i.e., the force of infection (FOI), is essential for assessing transmission risk and reconstructing distribution of immunity in a population.

View Article and Find Full Text PDF

An MRI-guided stereotactic neurosurgical robotic system for semi-enclosed head coils.

J Robot Surg

December 2024

National Engineering Research Center of Neuromodulation, School of Aerospace Engineering, Tsinghua University, Beijing, 100084, China.

Magnetic resonance imaging (MRI) offers high-quality soft tissue imaging without radiation exposure, which allows stereotactic techniques to significantly improve outcomes in cranial surgeries, particularly in deep brain stimulation (DBS) procedures. However, conventional stereotactic neurosurgeries often rely on mechanical stereotactic head frames and preoperative imaging, leading to suboptimal results due to the invisibility and the contact with patient's head, which may cause additional harm. This paper presents a frameless, MRI-guided stereotactic neurosurgical robotic system.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!