A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The development of a quantitative ELISA for antibodies against human platelet antigen type 1a. | LitMetric

The development of a quantitative ELISA for antibodies against human platelet antigen type 1a.

Transfusion

Immunihaematology Research Group, R & D Directorate, Scottish National Blood Transfusion Service, Edinburgh, Scotland.

Published: March 2003

Background: Severe neonatal alloimmune thrombocytopenia is often due to antibodies against human platelet antigen type 1a (HPA-1a). The aim of this study was to develop a quantitative ELISA for the measurement of antibodies against HPA-1a.

Study Design And Methods: HPA-1a glycoprotein (GP) IIb-IIIa was immobilized and mixed with recalcified anti-HPA-1a-positive plasma overnight at 4 degrees C. The beads were washed, the antibodies against HPA-1a were eluted, and the eluate pH level was promptly adjusted. The purified antibodies were dialyzed and used for the development of an ELISA incorporating HPA-1a-coated plates.

Results: Serial doubling dilutions of the purified antibodies resulted in consistent sigmoid standard curves with a sensitivity of 0.5 microg per mL. To determine the reproducibility of the ELISA, antibodies against HPA-1a in five plasma samples (Samples A-E) were measured at serial doubling dilutions in four separate assays. Three of the samples (Samples A-C) contained antibodies against HPA-1a. The mean amounts in microg per mL (+/- SD, percentage of CV) obtained in the four assays were as follows: Sample A, 133 (9.4, 7.1%); Sample B, 16.5 (1.7, 10%); and Sample C, 8 (0.8, 10%). The amounts in the two antibody-negative controls (Samples D and E) were consistently less than 0.2 microg per mL.

Conclusion: Using immobilized HPA-1a1a, antibodies against HPA-1a has been purified, and a quick and simple quantitative assay has been developed.

Download full-text PDF

Source
http://dx.doi.org/10.1046/j.1537-2995.2003.00322.xDOI Listing

Publication Analysis

Top Keywords

antibodies hpa-1a
16
antibodies
9
quantitative elisa
8
elisa antibodies
8
antibodies human
8
human platelet
8
platelet antigen
8
antigen type
8
purified antibodies
8
serial doubling
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!