Purpose: To evaluate intraocular pressure (IOP) variations after automated visual field examination in patients with primary open-angle glaucoma and in healthy subjects.

Patients And Methods: Intraocular pressure was measured in 49 patients (94 eyes) with primary open-angle glaucoma and in 13 healthy subjects (26 eyes) before and immediately after automated visual field examination. All patients had stable IOP and were using local medication to treat glaucoma. The visual field test was performed with a Humphrey 630 VF analyzer and the Central 30-2 full-threshold program.

Results: Mean IOP increased significantly in glaucomatous patients immediately after automated visual field examination (P < 0.01), and returned to pretest values after 1 hour (P = 0.2). Mean IOP variation was 2.38 (range, -6-11) mm Hg. In 42 (44.68%) glaucomatous eyes, IOP increased more than 2 mm Hg, with a mean increase of 5.5 mm Hg. Elderly glaucoma patients showed a significantly higher IOP rise than younger patients. No significant IOP variation was detected in healthy subjects.

Conclusion: Intraocular pressure varied significantly and tended to increase immediately after automated visual field examination in patients with primary open-angle glaucoma. Age seemed to contribute to these IOP changes, but other factors could be involved.

Download full-text PDF

Source
http://dx.doi.org/10.1097/00061198-200304000-00005DOI Listing

Publication Analysis

Top Keywords

visual field
24
field examination
20
open-angle glaucoma
16
intraocular pressure
16
automated visual
16
examination patients
12
primary open-angle
12
iop
8
patients primary
8
glaucoma healthy
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!