Background: Cardiac resynchronization therapy (CRT) has recently emerged as an effective treatment for patients with moderate to severe systolic heart failure and ventricular dyssynchrony. The purpose of the present study was to determine whether improvements in left ventricular (LV) size and function were associated with CRT.

Methods And Results: Doppler echocardiograms were obtained at baseline and at 3 and 6 months after therapy in 323 patients enrolled in the Multicenter InSync Randomized Clinical Evaluation (MIRACLE) trial. Of these, 172 patients were randomized to CRT on and 151 patients to CRT off. Measurements were made of LV end-diastolic and end-systolic volumes, ejection fraction, LV mass, severity of mitral regurgitation (MR), peak transmitral velocities during early (E-wave) and late (A-wave) diastolic filling, and the myocardial performance index. At 6 months, CRT was associated with reduced end-diastolic and end-systolic volumes (both P<0.001), reduced LV mass (P<0.01), increased ejection fraction (P<0.001), reduced MR (P<0.001), and improved myocardial performance index (P<0.001) compared with control. beta-Blocker treatment status did not influence the effect of CRT. Improvements with CRT were greater in patients with a nonischemic versus ischemic cause of heart failure.

Conclusions: CRT in patients with moderate-to-severe heart failure who were treated with optimal medical therapy is associated with reverse LV remodeling, improved systolic and diastolic function, and decreased MR. LV remodeling likely contributes to the symptomatic benefits of CRT and may herald improved longer-term survival.

Download full-text PDF

Source
http://dx.doi.org/10.1161/01.CIR.0000065226.24159.E9DOI Listing

Publication Analysis

Top Keywords

cardiac resynchronization
8
resynchronization therapy
8
left ventricular
8
ventricular size
8
size function
8
heart failure
8
end-diastolic end-systolic
8
end-systolic volumes
8
therapy left
4
function chronic
4

Similar Publications

Cardiac implantable electronic devices (CIEDs), including pacemakers, implantable cardiac defibrillators (ICD), and cardiac resynchronization therapy (CRT) devices, regulate heart rate and rhythm in patients with cardiac conditions. With an aging population, CIED-related complications, especially pacemaker pocket infections, are rising. Risk factors include frailty, older age, and superficial device fixation, while risk mitigation involves larger pocket sizes, submuscular fixation, and absorbable antibacterial envelopes.

View Article and Find Full Text PDF

This paper reviews the literature on assessing electrical dyssynchrony for patient selection in cardiac resynchronization therapy (CRT). The guideline-recommended electrocardiographic (ECG) criteria for CRT are QRS duration and morphology, established through inclusion criteria in large CRT trials. However, both QRS duration and LBBB morphology have their shortcomings.

View Article and Find Full Text PDF

: Heart failure is the leading cause of hospital admission and mortality. Racial disparities have been demonstrated in various cardiovascular disorders; however, the data for in-hospital outcomes, complications, and procedural rates are limited. : Utilizing the National Inpatient Sample (NIS) database, this retrospective cohort study included adult patients admitted with a principal diagnosis of heart failure.

View Article and Find Full Text PDF

Purpose: Increasing life expectancy and advances in cancer treatment will lead to more patients needing both radiation therapy (RT) and cardiac implantable electronic devices (CIEDs). CIEDs, including pacemakers and defibrillators, are essential for managing cardiac arrhythmias and heart failure. Telemetric monitoring of CIEDs checks battery status, lead function, settings, and diagnostic data, thereby identifying software deviations or damage.

View Article and Find Full Text PDF

An infant with DiGeorge syndrome, multiple comorbidities, and truncus arteriosus type II underwent repair complicated by heart block necessitating placement of a dual-chamber bipolar pacing system with right ventricular leads and subsequent resynchronization with placement of left ventricular apical pacing leads. Resynchronization therapy improved QRS duration from 180 ms to 100 ms and ejection fraction from 25% to 54% over the course of 4 weeks with gradual return to normal function and eventual discharge.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!