A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Flow encoded NMR spectroscopy for quantification of metabolite flow in intact plants. | LitMetric

Flow encoded NMR spectroscopy for quantification of metabolite flow in intact plants.

J Magn Reson

Physikalisches Institut, Lehrstuhl für Experimentelle Physik V (Biophysik), Universität Würzburg, Am Hubland, Würzburg 97074, Germany.

Published: March 2003

An NMR flow quantification technique applicable to metabolite flow in plants is presented. It combines flow sensitive magnetization preparation with slice selective spectroscopy. Flow encoded NMR spectroscopy is described to quantify, for the first time, flow velocities of metabolites in plants non-invasively. Flow sensitivity is introduced by magnetization preparation based on a stimulated echo experiment, prior to slice selective spectroscopy. For flow quantification eight different flow-weighted spectra are collected. With this flow preparation very slow flow velocities down to 0.1mm/s can be detected and small amounts of flowing metabolites can be observed despite the large background signal of stationary and flowing water. Important sequence optimization steps include appropriate choice of experimental parameters used for flow encoding as well as complete balancing of eddy currents from the flow encoding gradients. The method was validated in phantom experiments and applied in vivo. Examples of quantitative flow measurements of water and metabolites in phantoms and plants are provided to demonstrate the reliability and the performance of flow encoded spectroscopy.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s1090-7807(02)00183-0DOI Listing

Publication Analysis

Top Keywords

flow
15
flow encoded
12
encoded nmr
8
nmr spectroscopy
8
metabolite flow
8
flow quantification
8
magnetization preparation
8
slice selective
8
selective spectroscopy
8
spectroscopy flow
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!