A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Nonlinear coded excitation method for ultrasound contrast imaging. | LitMetric

Nonlinear coded excitation method for ultrasound contrast imaging.

Ultrasound Med Biol

Department of Cardiology, Thoraxcentre, Erasmus MCRotterdam, Rotterdam, The Netherlands.

Published: February 2003

Coded excitation with compression on receive is used in medical ultrasound (US) imaging to increase signal-to-noise ratio (SNR) and penetration depth. We performed a computer simulation study to investigate if chirped pulse excitation can be applied in US contrast agent imaging to increase SNR and contrast-to-tissue ratio (CTR) and, thus, reduce contrast agent destruction and tissue harmonics. A new nonlinear compression technique is proposed that selectively compresses the second harmonic component of the response. We compared a chirp of 9.4-micros duration, 2-MHz centre frequency, 45% relative bandwidth to a Gaussian pulse with equal centre frequency and bandwidth. For peak pressures between 50 and 300 kPa, we found for resonant bubbles an increase in response between 10 and 13 dB. Moreover, the axial resolution after compression was comparable to axial resolution of conventional imaging. This effect was relatively insensitive to peak excitation pressure and was largest for bubbles having resonance frequency around the centre frequency of the excitation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0301-5629(02)00712-3DOI Listing

Publication Analysis

Top Keywords

centre frequency
12
coded excitation
8
imaging increase
8
contrast agent
8
axial resolution
8
excitation
5
nonlinear coded
4
excitation method
4
method ultrasound
4
ultrasound contrast
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!