Background: Magnetic resonance imaging (MRI) has been used as one of the diagnostic tools in the preoperative evaluation of rectal cancer. However, the usefulness of endorectal coil (ERC) compared with phased array coil (PA) MRI is still unknown.
Patients And Methods: Nineteen patients with rectal (17 patients) and anal (2 patients) tumors undergoing both ERC-MRI and PA-MRI preoperatively were included in the study. Seventeen patients had advanced stage tumors, and the remaining 2 had early stage tumors. The diagnostic accuracy of depth tumor invasion and lymph node metastasis were compared with reference to the histopathologic findings as the gold standard.
Results: ERC-MRI was evaluable in only 10 (52.6%) of 19 patients, because of difficulties in ERC placement, whereas PA-MRI could be obtained in all patients (100%). In 10 patients examined by both modalities, the diagnostic accuracy of depth of tumor invasion was 80% by ERC-MRI and 80% by PA-MRI. In lymph node staging, ERC yielded sensitivity of 100%, specificity of 62.5%, and overall accuracy of 70.0%. The corresponding values for PA-MRI were 50%, 100% and 90.0%, respectively. These figures were not significantly different between the two modalities.
Conclusions: ERC-MRI and PA-MRI showed similar diagnostic accuracy. ERC-MRI may be abandoned in the preoperative staging of patients with locally advanced anorectal tumors because of its limited clinical utility.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0002-9610(02)01405-8 | DOI Listing |
Int J Clin Oncol
January 2025
Translational Research Support Section, National Cancer Center Hospital East, Chiba, Japan.
Early cancer detection substantially improves the rate of patient survival; however, conventional screening methods are directed at single anatomical sites and focus primarily on a limited number of cancers, such as gastric, colorectal, lung, breast, and cervical cancer. Additionally, several cancers are inadequately screened, hindering early detection of 45.5% cases.
View Article and Find Full Text PDFJ Periodontal Res
January 2025
Department of Radiology, University of Michigan, Ann Arbor, Michigan, USA.
Aim: Ultrasonography (US) has shown accuracy in imaging healthy periodontium. This study aims to evaluate the feasibility and accuracy of US for estimating dimensions of inflamed periodontium induced by ligature and bacteria.
Methods: Periodontal tissues of maxillary as well as mandibular premolars and molars in six female mini pigs were treated with ligature and three strains of bacteria for 4-10 weeks.
Pak J Pharm Sci
January 2025
Department of Pathophysiology, Shanxi Medical University, Jinzhong, Shanxi Province, China.
This study investigates the prognostic value of serum biomarkers PD-L1 and IGFBP-2 in patients with esophageal carcinoma. It finds a significant positive correlation between these biomarkers and established tumor markers CEA and CYFRA21-1. The 3-year survival rate for the patient cohort was 45.
View Article and Find Full Text PDFJ Orthop Surg Res
January 2025
Department of Human Anatomy, Graduate School, Inner Mongolia Medical University, Hohhot, 010010, Inner Mongolia, China.
Purpose: The study aimed to develop a deep learning model for rapid, automated measurement of full-spine X-rays in adolescents with Adolescent Idiopathic Scoliosis (AIS). A significant challenge in this field is the time-consuming nature of manual measurements and the inter-individual variability in these measurements. To address these challenges, we utilized RTMpose deep learning technology to automate the process.
View Article and Find Full Text PDFOrphanet J Rare Dis
January 2025
Department of Genetics and Metabolism, Children's Hospital of Zhejiang University School of Medicine, National Clinical Research Center for Child Health, No. 3333 Binsheng Road, Binjiang District, Hangzhou, 310053, Zhejiang, China.
Purpose: To enhance the detection rate of Neonatal Intrahepatic Cholestasis caused by Citrin Deficiency (NICCD) through newborn screening (NBS), we analyzed the metabolic profiles of missed patients and proposed a more reliable method for early diagnosis.
Methods: In this retrospective study, NICCD patients were classified into "Newborn Screening" (64 individuals) and "Missed Screening" (52 individuals) groups. Metabolic profiles were analyzed using the non-derivatized MS/MS Kit, and genetic mutations were identified via next-generation sequencing and confirmed by Sanger sequencing.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!