Superresolution by use of code division multiplexing.

Appl Opt

Department of Physical Electronics, Faculty of Engineering, Tel Aviv University, 69978 Tel Aviv, Israel.

Published: March 2003

Traditional methods for superresolution have sacrificed field of view for resolution. These methods multiplexed different parts of signals' spectrum on different carriers, and thus managed to transfer a wider range of frequency, in a manner that is similar to frequency division multiplexing in classical communication. We propose code division multiplexing for such an application, which has been shown to have superior capabilities. To enable such mutiplexing we propose a unique setup that creates an incoherent cosine transform of the image. A theoretical analysis of the setup is obtained and later compared with the empirical results.

Download full-text PDF

Source
http://dx.doi.org/10.1364/ao.42.001451DOI Listing

Publication Analysis

Top Keywords

division multiplexing
12
code division
8
superresolution code
4
multiplexing traditional
4
traditional methods
4
methods superresolution
4
superresolution sacrificed
4
sacrificed field
4
field view
4
view resolution
4

Similar Publications

Direct Frequency Comb Cavity Ring-Down Spectroscopy Using Vernier Filtering.

J Phys Chem A

January 2025

Division of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, California 91125, United States.

We present direct frequency comb cavity ring-down spectroscopy with Vernier filtering as a straightforward approach to sensitive and multiplexed trace gas detection. The high finesse cavity acts both to extend the interaction length with the sample and as a spectral filter, alleviating the need for dispersive elements or an interferometer. In this demonstration, a free running interband cascade laser was used to generate a comb centered at 3.

View Article and Find Full Text PDF

Enhancing Functional Breast Imaging: A sCMOS Camera-Based Lock-in Implementation for Dynamic Tomography.

J Biophotonics

January 2025

The College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin, China.

Diffuse optical tomography (DOT) enables the in vivo quantification of tissue chromophores, specifically the discernment of oxy- and deoxy-hemoglobin (HbO and HbR, correspondingly). This specific criterion is useful in detecting and predicting early-stage neoadjuvant breast cancer treatment response. To address the issues of the limited channels in the fiber-dependent breast DOT system and limited signal-to-noise ratio in the camera-dependent systems, we hereby present a camera-based lock-in detection scheme to achieve dynamic DOT with improved SNR, which adopted orthogonal frequency division multiplexing technology.

View Article and Find Full Text PDF

Background: Multiplex genetic testing is recommended when treating nonsmall cell lung cancer. A certain percentage of test failures in RNA assays owing to poor surgical specimen quality have been documented, and fixation failure is a possible cause. At our institution, sheet-like fixation is performed to reduce fixation time.

View Article and Find Full Text PDF

Background: Bacterial lower respiratory tract infection, particularly ventilator-associated pneumonia (VAP), is a significant cause of morbidity and mortality in children who require mechanical ventilation (MV). Microbiologic diagnosis has relied on bacterial culture, but reverse transcriptase polymerase chain reaction (RT-PCR) with bacterial targets is now available for clinical use. We compared the diagnostic performance of tracheal aspirate (TA) multiplex RT-PCR to culture in children requiring MV with suspected lower respiratory tract infection.

View Article and Find Full Text PDF

Background/objectives: Conventional live oral poliovirus vaccines (OPVs) effectively prevent poliomyelitis. These vaccines are derived from three attenuated Sabin strains of poliovirus, which can revert within the first week of replication to a neurovirulent phenotype, leading to sporadic cases of vaccine-associated paralytic poliomyelitis (VAPP) among vaccinees and their contacts. A novel OPV2 vaccine (nOPV2) with enhanced genetic stability was developed recently; type 1 and type 3 nOPV strains were engineered using the nOPV2 genome as a backbone by replacing the capsid precursor polyprotein (P1) with that of Sabin strains type 1 and type 3, respectively.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!