A nationwide radon survey was conducted to provide data on the annual average indoor radon concentration in Korean homes. This survey also provided data on the variation of radon concentration with season, house type, and building age. The arithmetic mean (AM) of annual radon concentration in Korean homes was 53.4 +/- 57.5 Bq m(-3). The indoor radon concentration showed a lognormal distribution with a geometric mean (GM) and its standard deviation (GSD) of 43.3 +/- 1.8 Bq m(-3). The radon concentrations in the traditional Korean-style houses were about two times higher than those in apartments and row houses. The average annual outdoor radon concentration was 23.3 Bq m(-3). The average annual effective dose to the general public from radon was 1.63 mSv y(-1).

Download full-text PDF

Source
http://dx.doi.org/10.1097/00004032-200303000-00008DOI Listing

Publication Analysis

Top Keywords

radon concentration
20
radon
9
indoor radon
8
concentration korean
8
korean homes
8
average annual
8
concentration
5
nationwide survey
4
survey radon
4
radon levels
4

Similar Publications

In different measurement tasks, the duration allocated for radon progeny concentration measurement varies, and the requirements for measurement precision also differ. To accommodate the needs of various radon progeny concentration measurement tasks, this study takes the error in radon progeny concentration measurement as the optimization goal and the time points of the three-stage method as the optimization target, establishing an optimized three-stage method for radon progeny concentration measurement. The optimization algorithm allocates the three time periods under any total measurement time requirement, ensuring the highest measurement precision.

View Article and Find Full Text PDF

This study assesses the activity concentrations of the radionuclides 238U, 232Th, and 40K in soil samples collected from Wolaita Sodo town, located in the Southern Nations, Nationalities, and Peoples' (SNNP) Region, Ethiopia. A gamma-ray spectrometer equipped with a NaI(Tl) detector was used for the measurements. The concentrations of 238U, 232Th, and 40K varied from 3.

View Article and Find Full Text PDF

Exhalation of Rn-219 by patients treated with Radium-223.

EJNMMI Phys

January 2025

Department for Radiation Protection and Medical Physics, Hannover Medical School, Carl-Neuberg- Str. 1, 30625, Hannover, Germany.

Background: Treatment with Ra-223 dichloride is approved for the therapy of castration resistant prostate cancer (CRPC) with symptomatic bone metastases and no known visceral metastases in Europe since 2013, and Ra-223 is under discussion for labelling other molecules and nanoparticles. The direct progeny of Ra-223 is Rn-219, also known as actinon, a radioactive noble gas with a half-life of 3.98 s.

View Article and Find Full Text PDF

An activity concentration-based proposal for radon management in workplaces involving NORM in Canada.

Radiat Environ Biophys

December 2024

Radiation Protection Bureau, Health Canada, 775 Brookfield Road, Ottawa, ON, K1A 1C1, Canada.

The Canadian Guidelines for the Management of Naturally Occurring Radioactive Materials (NORM) have been developed to manage radiation doses received in workplaces involving NORM, such as mineral extraction and processing, oil and gas production, metal recycling or water treatment facilities. This management strategy works well for most naturally occurring radioactive materials in workplaces, with the exception of radon. Radon is a naturally occurring radioactive gas generated by the decay of uranium-bearing minerals in rocks and soils.

View Article and Find Full Text PDF

RADON in a high karst area of Montenegro - A case study.

Appl Radiat Isot

March 2025

School of Applied Mathematics and Informatics, University of Osijek, Trg Ljudevita Gaja 6, Osijek, Croatia.

The national radon surveys in Montenegro revealed that the highest annual average radon concentrations (C) in ground floors of dwellings and schools were found in a rural region characterized as a typical high-karst area. In this region, spanning approximately 800 km, C values in 9 houses and 16 schools ranged from 219 to 2494 Bq/m, with AM = 977 Bq/m. To investigate the causes of these elevated indoor radon concentrations, the following parameters were measured near the 25 surveyed buildings: soil humidity, electrical conductivity, pH, activity concentrations of Ra, U, U, Th and K, radon concentration in soil gas (c), soil permeability for radon gas (k), and gamma dose rate in the air.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!