Background: Implantation of small aortic valve prostheses has been reported to be associated with impaired left ventricular (LV) mass regression and incomplete resolution of symptoms although these data have been generated largely with male patients. Therefore we sought to determine the clinical and hemodynamic outcomes of female patients who received a 19-mm aortic valve.

Methods: Between May 1995 and December 2000, 38 female patients (average age 73 years, range 42 to 89) underwent isolated aortic valve replacement (AVR; n = 22) or AVR plus coronary artery bypass graft surgery (CABG; n = 16) with a 19-mm aortic prosthesis. The average New York Heart Association (NYHA) class was 3.08 and of the 26 patients who had angina, 47.2% were in CCS class III or IV. Clinical and echocardiographic follow-up was done an average of 33.4 months (8 to 72) after surgery.

Results: Operative mortality was 10.5%. Overall survival at an average of 33 months was 71.1%. The average NYHA class was 1.52 +/- 0.34 postoperatively (p < 0.001 versus preoperative) and 95% had no anginal symptoms or were in Canadian Cardiovascular Society class I. The LV mass index showed significant regression (114 +/- 11 g/m2 to 89 +/- 9 g/m2, p = 0.001) despite an effective orifice area index (EOAI) of 0.64 +/- 0.09 cm2/m2.

Conclusions: Despite a very small EOAI, elderly female patients with 19-mm prosthetic aortic valves can experience a satisfactory improvement in symptoms and normalization of LV mass. This finding suggests that small prosthetic aortic valves continue to have an application in contemporary cardiac surgical practice. The current perception of patient-prosthesis mismatch may need to be reconsidered for select populations.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0003-4975(02)04079-1DOI Listing

Publication Analysis

Top Keywords

prosthetic aortic
12
aortic valves
12
female patients
12
left ventricular
8
ventricular mass
8
aortic valve
8
mass regression
8
19-mm aortic
8
nyha class
8
+/- g/m2
8

Similar Publications

Background: Transcatheter closure of percutaneous paravalvular leak (PVL) is a technically challenging procedure, especially after surgical mechanical valve replacements (SMVR), as the risk of interference with the prosthetic valve discs and the complex interventional techniques required for mitral PVL closure. Our study was designed to review the results with transcatheter closure of PVL after SMVR.

Methods: From January 2018 through December 2023, a total of 64 patients with PVL after SMVR underwent transcatheter closure with the help of preoperative 3-dimensional printing model and simulator for image evaluation.

View Article and Find Full Text PDF

Analysis of the haemodynamic changes caused by surgical and transcatheter aortic valve replacements by means fluid-structure interaction simulations.

Comput Biol Med

January 2025

UCL Mechanical Engineering, University College London, UK; Ri.MED Foundation, Palermo, Italy; University of Palermo, Department of Engineering, Palermo, Italy. Electronic address:

Aortic valve replacements, both surgical and transcatheter, are nowadays widely employed treatments. Although clinically effective, these procedures are correlated with potentially severe clinical complications which can be associated with the non-physiological haemodynamics that they establish. In this work, the fluid dynamics changes produced by surgical and transcatheter aortic valve replacements are analysed and compared with an ideal healthy native valve configuration, employing advanced fluid-structure interaction (FSI) simulations.

View Article and Find Full Text PDF

Background: Surgical aortic valve replacement (SAVR) is the commonly used approach for aortic valve replacement (AVR) in patients with aortic stenosis at low or intermediate surgical risk. However, transcatheter aortic valve replacement (TAVR) has emerged as an alternative to SAVR for AVR. This meta-analysis aims to assess the comparative efficacy and safety of TAVR versus SAVR in low-to-intermediate surgical risk patients by analyzing temporal trends in the outcomes of TAVR and SAVR at various follow-up intervals, providing a more detailed understanding.

View Article and Find Full Text PDF

Aortic valve leaflet assessment to inform novel bioinspired materials: Understanding the impact of collagen fibres on the tissue's mechanical behaviour.

J Mech Behav Biomed Mater

December 2024

Trinity Centre for Biomedical Engineering, Trinity Biomedical Sciences Institute, Trinity College Dublin, 2, Dublin, Ireland; Discipline of Mechanical, Manufacturing, and Biomedical Engineering, School of Engineering, Trinity College Dublin, 2, Dublin, Ireland; Advanced Materials and Bioengineering Research Centre (AMBER), Trinity College Dublin, Ireland. Electronic address:

Aortic stenosis is a prevalent disease that is treated with either mechanical or bioprosthetic valve replacement devices. However, these implants can experience problems with either functionality in the case of mechanical valves or long-term durability in the case of bioprosthetic valves. To enhance next generation prosthetic valves, such as biomimetic polymeric valves, an improved understanding of the native aortic valve leaflet structure and mechanical response is required to provide much needed benchmarks for future device development.

View Article and Find Full Text PDF

Percutaneous valve implantation or surgical replacement with mechanical or biological valves are standard therapies for severe valvular heart diseases. Prosthetic valve thrombosis, though rare, is a serious complication, particularly with mechanical prostheses. This study aimed to investigate the predictive value of platelet volume parameters, including mean platelet volume (MPV), platelet distribution width (PDW), and platelet-large cell ratio (P-LCR), for valvular thrombosis risk in patients undergoing valve replacement therapy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!